Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 14 of 108
DANGER!
Fire hazard due to overload or sparking!
Fire hazards occur due to overloaded cables, electrical arcs, short circuits or sparking.
Sparking can occur with poorly serviced, contaminated conductor rails or if the installation does
not comply with the required tolerances.
→
Permissible current values must be observed.
→
Comply with tolerances during installation.
→
Design and dimension systems according to the permissible system load capacity and
provide appropriate protection devices.
→
Do not store combustible and/or easily ignited materials near conductor rails.
→
Check, service and clean conductor rails regularly and as prescribed. See Section 8 and 9
2.8.2
Mechanical hazards and sources of danger
DANGER!
Risk of injury due to ensnarement or impact!
An ensnarement and/or impact with moving conductor rails (slip ring) or current collectors
connected to the machine and other components must be prevented.
→
Cordon off the work area.
→
Use caution when working in the vicinity of the danger zone, in particular if protective
devices (covers, enclosures, control devices, etc.) have been removed or deactivated.
→
Use caution when working in the vicinity of the danger zone, particularly below the
conductor rail.
→
Wear personal protective equipment!
WARNING!
Secure components against falling!
Possible falling components must be determined in the customer analysis as part of the operator's
risk and hazard analysis.
→
The operator must take appropriate measures.