Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 11 of 108
◼
The conductor rail should preferably be installed horizontally with current collector insertion from below. With indoor areas, it is
also possible to insert the current collector from the side (use current collector for lateral insertion).
Electrical engineering operating requirements
◼
The electrical system must be secured in compliance with the locally applicable regulations.
2.5
Unintended use
Claims of any kind due to damage incurred during use that deviates from the intended use described above ("use other than the
intended use") are excluded. The operator bears sole liability for all damage that results from unintended use.
Unintended use particularly includes the following forms of use:
◼
Operation in unsuitable environmental conditions (see Section 3.3). The conductor rail system may
only
be operated under the
environmental conditions described in the Section 3 .
◼
Operation in an area accessible to the public.
◼
Operation within manual reach.
◼
Use in non-industrial applications.
◼
Overloading of the conductor rails by excessive current or voltage.
◼
Overloading of individual current collectors by excessive current or voltage.
◼
Use as a walking or climbing aid.
◼
Walking on the conductor rail.
◼
Use of unsuitable cleaning agents (e.g., silicone oils or aromatic compounds).
◼
Use of the system with accessories that are not approved and not authorized by the manufacturer.
◼
Use of the system by untrained personnel.