XLiner Duo/Combo 360
CARE AND MAINTENANCE
Maintenance of the following recommendations will extend the life
of the device:
- Transport and carry the product only with locked compensator.
- Keep the product clean and protected from any bumps, dust and
dampness; do not allow getting moisture, dust or other dirt inside of
the product.
- In case if any moisture goes into the product, remove the batteries
and take it to the service center.
- Do not keep or use the device for a long time at high humidity
conditions.
- Keep the instrument clean and wipe it with a clean and soft cloth.
Mishandling of the following rules can cause electrolite leakage
from the batteries or other damages:
- Remove the batteries from the product if you do not use it for a long
time.
- Do not use different battery types with different charge levels.
- Do not leave discharged batteries in the product.
Check of vertical line
Use a plumb bob as a reference of a vertical line. Place the laser level at
a 1,5m distance from the plumb bob (see Fig. E).
1. Move compensator lock to
ON
position , then switch on vertical
plane and align vertical laser line with the low point of plumb bob.
2. If deviation between the laser line and the plumb line exceeds 0.2
mm per 1m of the plumb bob length (for a 2.5m plumb bob deviation
shouldn’t exceed 0.5 mm) please contact service center.