64
Product specifications
10 Product specifications
10.1 Technical data
Condair RH
Type
RH 1.8
RH 3.6
Max. steam capacity
1.8 kg/h
3.6 kg/h
Max. power consumption
1.4 kW
2.9 kW
Heating voltage
230 V1 /50..60Hz
Control voltage
230 V1 /50..60Hz
Operating data
Admissible control signals
0-10V, 2-10V, 0-20mA, 4-20mA
Admissible water pressure
2 - 6 bar (200 kPa - 600 kPa)
Water quality
Untreated drinking water
with a conductivity of 125...1250 uS
Admissible water temperature
4 - 30° C
Admissible ambient temperature
4 - 30° C
Admissible ambient humidity
max.75%hr
Max. admissible duct pressure
-0.8 kPa…0.8 kPa
Drain temperature
<60°C (integrated drain water cooling)
Protection class
IP20
Conformity
CE
Unit connections
Water supply connection
3/4" (External thread)
Water drain connection
ø20 mm
Steam outlet connection
ø22 mm
Electrical connections
230V
via integrated mains cable
230V
via electrical isolator
Dimensions and weights
Operating weight empty
8.6 kg
Operating weight filled
11.5 kg
Unit height
467 mm
Unit width
265 mm
Unit depth
175 mm