Quality control:
Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that
recognizes the fixture.
EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES
for correct assembly, proceed as follows:
1) avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant
water can accumulate.
Picture 2
2) make a suitably-sized hole (core) in the ground.
3) square the upper part of the hole by inserting a prefabricated pit of approximately
25x25x25cm (G/D1), 30x30x30cm (G/D2) or 40x40x40cm (G/D3).
The upper edge of the pit must be about 2/3 cm (G/D1-2) or 3/4 cm (G/D3) higher
than
the surrounding ground to which it must be connected with an outer slope for the
run-off of water and to avoid the accumulation of dirt.
4) fill the core with a mixture of sand and gravel up to approximately 20cm (G/D1),
25cm (G/D2) or 35cm (G/D3) from the upper edge of the pit. Hose with plenty of
water until refusal and tamp the mixture in such a way as to form a compact and
homogenous draining layer.
5) place four bricks with cement into the pit thus created in order to create a solid
foundation
for the recess box, which should jut out with respect to the level of prefabricated
pit by approximately 2/3 cm.
6) backfill the pit around the casing with a mixture of well tamped and set sand and
gravel, arranging the cables for the electrical connection of the fixture.
EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES
proceed as in the above points 1-2-3-4.
5) refer to pict.3, Make a lean concrete mix onto which the foundation block can be
laid, taking care to leave a hole in the centre of at least 6cm (G/D1), 12cm (G/D2)
or 20cm (G/D3) in diameter for drainage. Provide for the passage of electrical wires.
6)
insert the outer casing of the fixture into a concrete foundation block, batched at 200
kg of 325 type cement per cubic metre of mixture. The block must have a diameter
(or side) of not less than 30 cm. Line up carefully the upper edge of the outer casing
with the trampling level as per pict. 3.
ELECTRICAL CONNECTION
Important: the electrical connection must be carried out by a skilled electrician.
Important: in the case of damage of the appliance, there may be a reduction in the
degree of protection with consequent infiltration of water and loss of insulation.
Therefore, additional protection should be inserted into the electrical plant against
direct contacts (for example a high sensitivity differential switch). During installation,
fully respect the current rules on electrical systems.
• For the electrical connection use a flexible <HAR> rubber cable cross-section
1x1,5mm
2
.
The fixtures are complete with a piece of H05RN-F (G/D1) or H07RN-F (G/D2-3)
cable which is pre-connected and sealed. For a rapid and safe connection with the
electric line use the connector 4068964 or an equivalent system that guarantees at
least the IP67 degree.
• it is essential a frequent cleaning of the glass and of the outer surface of the fixture
to avoid build up of mud and dirtiness resulting in dangerous overheating due to
uncorrect light and heath dissipation.
• important: in the event of damage to the H07RN-F cable, breakage of the screen,
infiltration of water, the appliance cannot be used. Disconnect it from the mains
supply and contact our company or our sales organization for replacement/repair.
tmax. glas Temp. ta 25°C
40° C
40° C
50° C
40° C
40° C
50° C
Fixtures that can be utilized in all accessible areas, according to EN60598-2-13
Pedestrian over, with max. glass temp. of 75°C
20kN static load resistance.
• Do not install in areas where snowplows are used.
Features and meaning of the symbols shown on the label:
• lighting appliance for indoor and outdoor ground-recessed installation.
Capable of withstanding the load of motor vehicles with inflatable tyres pumped with
air, maximum weight static or dynamic: 2000Kg
version Class I
Pathe G/DD1
Pathe G/DD2
Pathe G/DD3
Pathe G/DQ1
Pathe G/DQ2
Pathe G/DQ3
ORIENTING THE LIGHT BEAM
Caution: During the installation stage (drive-over or not), check that the fixture is
orientated
so that the light beam is directed in the desired way (pict. 4).
pict. 1
YES
G/DD
NO
G/DQ
Pathe G/DD1
Pathe G/DD2
Pathe G/DD3
Pathe G/DQ1
Pathe G/DQ2
Pathe G/DQ3
200
245
45
Ø270
Ø 215
Ø215
200
245
45
Ø270
Ø 215
Ø215
93
12
5
32
Ø 170
Ø 145
Ø 145
95
Ø 95
Ø 120
75
20
Ø 95
93
12
5
32
Ø 170
Ø 145
Ø 145
95
Ø 95
Ø 120
75
20
Ø 95
35 cm
(G/DM3)
30 cm
(G/DM1)
upper casing
level flushing
to roadside
concrete block
lean concrete
draining layer
recess box
connection
accessory 4068964
electric cables
8 mm (G/DM3)
2.5 mm (G/DM1)
frame
pict. 3
TOP VIEW pict
. 4
well-settled sand
and gravel filling
recess box
drainage foundations
made of sand and
gravel soaked to
saturation, well
settled
support bricks
secured in place
with cement
connection
accessory 4068964
electric cables
2
÷
3
c
m
(G/D1
-
G/D2)
3
÷
4
c
m
(G/D3)
pict. 2
prefabricated pit
25x25x25cm approx (G/D1)
30x30x30cm approx (
G/D2
)
40x40x40cm approx (
G/D3
)
MI/1881-C
- 1
a
ed