RAP-100 Remote Access Panel
ODU Operation
Rev. 1
3–9
3.2.29 (ODU,ENABLE,1:1,CSAT#1,CONFIG,RECEIVER,LNA)
FAULT-LOGIC
(ODU,ENABLE,1:1,CSAT#2,CONFIG,RECEIVER,LNA)
FAULT-LOGIC
(ODU,ENABLE,STAND-ALONE,CONFIG,RECEIVER,LNA)
FAULT-LOGIC
SELECT LNA FAULT LOGIC:
SUMMARY NO SUMM (ENTER)
The user is prompted to select either SUMMARY or NO SUMM, using the
LEFT/RIGHT arrow keys, then to press ENTER. This controls whether or not the a LNA
Current-Window fault will activate the SUMMARY FAULT RELAY. This allows the
user to select whether or not to switch the ONLINE/OFFLINE CSAT in the event of a
LNA current-window fault.
3.2.30 (ODU,ENABLE,1:1,CSAT#1,CONFIG)
MISCELLANEOUS
(ODU,ENABLE,1:1,CSAT#2,CONFIG)
MISCELLANEOUS
(ODU,ENABLE,STAND-ALONE,CONFIG)
MISCELLANEOUS
MISC: COLD-START AFR
XREF REF-ADJUST RTC
This menu item is used to select miscellaneous ODU parameter for modification. Use the
LEFT/RIGHT arrow keys, then press ENTER.
3.2.31 (ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS)
COLD-START
(ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS)
COLD-START
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS)
COLD-START
SELECT COLD START STATE:
ENABLED DISABLED (ENTER)
The user is prompted to select either ENABLED or DISABLED, using the LEFT/RIGHT
arrow keys, then to press ENTER.
3.2.32
(ODU,ENABLE,1:1,CSAT#1,CONFIG,MISCELLANEOUS)
AFR(Auto Flt Rec)
(ODU,ENABLE,1:1,CSAT#2,CONFIG,MISCELLANEOUS)
AFR(Auto Flt Rec)
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS) AFR(Auto Flt Rec)
SEL AUTO FAULT RECOVERY:
ENABLED DISABLED (ENTER)
The user is prompted to select either ENABLED or DISABLED, using the LEFT/RIGHT
arrow keys, then to press ENTER.