Troubleshooting Tips
Memotec Inc.
6-3
Console connection
does not work, with:
POWER
LED green
STATUS
LED amber
ALARM
LED any state
Incorrect cable connection
Make sure you are using the
factory-supplied console
cable
Make sure the cable is prop-
erly plugged into the
CON-
SOLE
port and the console
terminal COM port
HyperTerminal communica-
tions program
Change
Emulation
parameter
setting from
Auto detect
to
ANSI
(see )
Incorrect modem setting
Set the modem to ignore
DTR: execute the AT com-
mand
at&d0
Set the modem to Auto
Answer mode: execute
ats0=1
Console terminal dis-
plays unreadable char-
acters
Console terminal was not set to
the default console speed
before startup
Set your console terminal
emulator to 9600 bps, and
start again
LAN connection does
not work
No power to LAN hub
Make sure the power outlet
has power
Make sure the LAN hub is
properly plugged in and
switched on
Incorrect cable connection
If
LINK
LED is off, check LAN
cable and replace if damaged
If
LINK
LED is on, make sure
you are using the correct IP
address for transmissions
Symptom
Possible Problem
Solution
Summary of Contents for NetPerformer SDM-9 Series
Page 1: ...NetPerformer SDM 9120 9220 9230 Series Hardware Installation Guide ...
Page 10: ...Memotec Inc ...
Page 11: ...Memotec Inc 1 1 1 Preface ...
Page 21: ...2 Memotec Inc 2 1 Unpacking ...
Page 27: ...3 Memotec Inc 3 1 Hardware Installation ...
Page 62: ...SDM 9XXX Series Hardware Installation Guide 3 36 Memotec Inc ...
Page 63: ...4 Memotec Inc 4 1 Product Description ...
Page 99: ...5 Memotec Inc 5 1 Serial Port and User Equipment Connections ...
Page 108: ...SDM 9XXX Series Hardware Installation Guide 5 10 Memotec Inc ...
Page 109: ...6 Memotec Inc 6 1 Troubleshooting Tips ...
Page 117: ...B Memotec Inc B 1 Appendix B Compliance Information and Safety Warning ...
Page 121: ...Memotec Inc B 5 ...
Page 128: ...SDM 9XXX Series Hardware Installation Guide B 12 Memotec Inc ...
Page 133: ...Memotec Inc B 17 Compliance to China RoHS ...
Page 135: ...Memotec Inc B 19 ...