DT4572 X-Band Down Converter
Rev. 0
Remote Control
MM/DT4572.IOM
60
Command
Details
Initialize Command:
<DEV/ICT
_
xx_yy'cr'
Confirmation: >DEV/ICT
_
xx_yy'cr''lf']
Initialize Status:
<DEV/ICT_'cr'
Confirmation: >DEV/ICT
_
xx_yy'cr''lf']
xx = chain position = 01 to 12, or BU. Where BUselects the
converter as the backup.
yy = chain length for xx = BU (i.e. Backup Converter) 01 to 12.
yy = P1 or P2, single or dual polarity
Example 1:
The following command assigns the converter chain position "1".
<DEV/ICT_01'cr'
>DEV/ICT_01'cr''lf']
Example 2:
The following command assigns the receiving converter as the backup
converter in a 1:8 system.
<DEV/ICT_BU_08'cr'
>DEV/ICT_BU_08'cr''lf']
It should be reiterated that only the converter physically located at the top of a redundant
rack should be assigned as the Backup unit. Likewise, assignment of chain positions in a
redundant rack should be made according to the physical allocation of each converter in
the rack (i.e. The top converter should be the Backup, the second converter should be
assigned chain position 1, the third converter position 2, etc.).
B.6.3.2 A
UTOMATIC
/M
ANUAL
M
ODE
This command provides for automatic switching by the backup Converter if both units
are in the Redundancy Mode. This command is only accepted by the backup Converter.
If a chain converter is set in Manual Mode, the backup Converter will log the occurrence
and not act upon further information from the converter until put into Automatic Mode.
The default is off.
Command
Details
Automatic Mode:
<DEV/SAM
_
xx_y'cr'
Confirmation: >DEV/SAM_xx_y'cr''lf']
Automatic Status:
<DEV/SAM
_
xx_'cr'
Confirmation: >DEV/SAM
_
xx_y'cr''lf']
Where: xx = 01 to 12, converter number
y = A for Auto; M for Manual
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...