DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Serial Interface Operation
Revision 2
8–11
8.7.1.5
Stored Alarm Queries Quick Reference
Sect.
Item
Description
Syntax
TSA
Return Total Stored Alarms
<DEV/TSA_{cr}
CAA
Clear All Stored Alarms
<DEV/CAA_YES{cr}
LAA
List All Stored Alarms
<DEV/LAA_{cr}
8.7.2
Utility Commands/Queries
8.7.2.1
TIM (Time)
Use TIM to set or return the time.
Description
Details
Set Time:
<DEV/TIM_hh:mm:ss{cr} where:
hh=Hour
mm=Minutes
ss=Seconds
Confirmation:
>DEV/TIM_hh:mm:ss{cr}{lf}]
Return Time:
<DEV/TIM_{cr}
Confirmation:
>DEV/TIM_hh:mm:ss{cr}{lf}]
8.7.2.2
DAT (Date)
Use DAT to set or return the date.
Description
Details
Set Date:
<DEV/DAT_mm/dd/yy{cr} where:
mm=Month
dd=Day
yy=Year
Confirmation:
>DEV/DAT_mm/dd/yy{cr}{lf}]
Return Date:
<DEV/DAT_{cr}
Confirmation:
>DEV/DAT_mm/dd/yy{cr}{lf}]