Use the
◄
►
arrow keys to select NO or YES, and then press [ENT]. If you select YES, this will
overwrite the existing configuration at the selected location.
6.2.5.2 STORE/LD: LOAD
LOAD CONFIGURATION FROM
LOCATION: 10 (ENTER)
Use the
▲
▼
arrow keys to select the location from where to load the desired configuration,
and then press [ENT]. Locations 1 through 10 are available. If the location contains a valid stored
configuration, this message displays:
THE NEW CONFIGURATION
HAS BEEN LOADED (ENTER)
Press [ENT] or [CLR] to return to the previous menu. If, however, the selected location does not
contain a previously stored configuration, this message displays:
WARNING! LOC 10 CONTAINS
NO DATA! (ENTER)
Press [ENT] or [CLR] to return to the previous menu.
6.2.6 SELECT: UTILITY
UTILITY: SET-RTC DISPLAY
SWITCH-ID TEST RELAY (ENT)
Use the
◄
►
arrow keys to select from the choices shown, and then press [ENT]. This submenu
permits you to select from a number of different utility functions.
6.2.6.1 UTILITY: SET- RTC (Set Real-Time Clock)
EDIT REAL TIME CLOCK:
12:00:00 24/04/14 (ENT)
To edit the time and date: Use the
◄
►
arrow keys to select a digit, and then use the
▲
▼
arrow keys to edit that value. Press [ENT] when done. Note that the date is shown in
DD/MM/YY format, in accordance with international convention.
6.2.6.2 UTILITY: DISPLAY (Display Brightness)
EDIT DISPLAY BRIGHTNESS:
100% (PRESS ENTER)
Use the
▲
▼
arrow keys to select a VFD brightness level of 25%, 50%, 75% or 100%, and then
press [ENT].
Summary of Contents for CRS-300
Page 16: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Table of Contents Revision 19 xvi BLANK PAGE ...
Page 24: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Preface Revision 19 xxiv Notes ...
Page 48: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Introduction Revision 19 1 24 Notes ...
Page 82: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 10 Notes ...
Page 88: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 16 Notes ...
Page 112: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 40 Notes ...
Page 122: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 50 Notes ...
Page 138: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 66 Notes ...
Page 144: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 72 Notes ...
Page 156: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 84 Notes ...
Page 162: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 90 Notes ...
Page 237: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix A Revision 19 A 7 BLANK PAGE ...
Page 244: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix A Revision 19 A 14 Notes ...
Page 282: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix B Revision 19 B 38 Notes ...
Page 292: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix C Revision 19 C 10 BLANK PAGE ...
Page 296: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix C Revision 19 C 14 Notes ...
Page 297: ......
Page 298: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...