Physical Description
CDM-500 Closed Network Satellite Modem
4–2
Rev.
1.3
Table 4-1- Front Panel Led Indicators
LED
Color
Condition
Red
A Unit Fault exists (Example: PSU fault)
Orange
No Unit Faults, but a Traffic Fault exists
Unit Status
Green
No Unit Faults, or Traffic Faults
Green
No Tx Traffic Faults
Transmit
Traffic
Off
A Tx Traffic fault exists
OR the Tx Carrier is in OFF state
Green
No Rx Traffic Faults (demod and Viterbi decoder are
locked, everything is OK)
Receive
Traffic
Off
An Rx Traffic fault exists (the demod may still be OK)
Green
The Unit is On Line, and carrying traffic
On line
Off
The Unit is Off Line (standby) - forced by externally
connected 1:1 or 1:N redundancy system
Orange
There is a Stored Event in the log, which can be viewed
from the front panel, or retrieved via the remote control
interface
Stored
Event
Off
There are no Stored Events
Orange
The Unit is in Remote Mode - local monitoring is
possible, but no local control
Remote
Off
The Unit is in Local Mode - remote monitoring is
possible, but no remote control
Orange
Framing on, EDMAC on, and unit defined as Slave
EDMAC
Mode
Off
Either no EDMAC, EDMAC Master, or Transparent
mode is selected
Orange
A Test Mode is selected (Example: IF Loopback)
Test Mode
Off
There is no Test Mode currently selected
Figure 4-1 Front and Back panels