A short series of tones rising in pitch will be heard when switching to the UHF only frequency and a short 
series of tones decreasing in pitch are heard when switching to VHF only frequency.  The front LED light 
will also indicate which frequency the detector is set at by flashing at a different rate: just under once a 
second for 612/614 MHz, and just under 2 seconds for 139/139 MHz. The small antenna above the bar 
graph will also flash at a faster or slower rate depending on the frequency selected. Note that the LED 
and antenna indicators only provide useful information when the device is set to a single frequency. 

Marker vs M3 Detection 

Approximately every one second the QAM Shadow

TM

 scans for both Marker and M3 leakage 

simultaneously, one second for each band.  The design intent is to simply the operation by eliminating 
the need to put the QAM Shadow

TM

 into a special M3 mode of operation. If a signal from a Marker is 

detected at one or both frequencies, the QAM Shadow

TM

 will produce the appropriate warble for each 

marker detected. However if a M3 leakage signal is detected, it always takes priority over a Marker 
signal (at the same frequency); therefore the QAM Shadow

TM

 will only provide a M3 warble.  In other 

words, if a Marker and a M3 leak were found at the same frequency band, the QAM Shadow

TM

 will only 

warble and display the information related to the M3 leak.  In another scenario where there is a Marker 
signal on one frequency band and a M3 signal on the other band, the QAM Shadow

TM

 will then warble 

and display the level for each of the two signals as it alternates back and forth between bands.  If this 
occurs, it is recommended that the tech switch the mode of operation to a single frequency band to 
either monitor the Marker or M3.  The reasoning behind the M3 priority is to allow a technician who is 
using an M3 to troubleshoot or qualify a network to mask out the unwanted Marker detection.  They 
only are interested in finding M3 leakage. 

Leakage measurements are displayed in large, easy to 
read numbers. The leakage level bar indicator on the left 
of the display shows the relative leakage level. If an RF 
field is present but does not contain the QAM Marker

TM

 

or M3 signal, “NOISE” will be displayed above the 
numbers.  If the QAM Marker

TM

 or M3 signal is 

detected, “LEAKAGE” is displayed.  In addition, if the M3 
signal is detected, the units of measure indicator (uV/m) 
will start flashing.  If the signal strength exceeds the 
Measure mode Squelch setting, the warble tone, based 
on the frequency and type of signal detected, will 
sound. 

 
A visual battery indicator is shown at the lower right corner of the display. The unit of measure is 
displayed below the signal strength numbers near the bottom of the screen. 

Volume Control:

  The volume level may be adjusted when the device is in Measure Mode.  A 

momentary press of the button will active the backlight. Subsequent presses of the button will then step 
the volume through the range of settings. The settings are: MUTE, 1, 2, 3, 4, and 5 with 1 representing 