8
SYDNEY Electronic Safe
EMERGENCY OPENING
WITH THE KEY
Remove the cover under the keyboard.
Insert one of the emergency opening keys.
Turn the emergency opening key towards left or
right. Now you can open the door.
PROGRAMMING
THE ELECTRONIC LOCK
Please note that the following programming opera-
tion should be performed only with the door open
and with the bolt work retracted.
Press twice the key
CLEAR
The display shows
ProG.
Now enter the function code 8-9-5-1-0-0.
The display shows
1
7
1
3
0
1
(a) (b)
(c) (d) (e) (f)
The following settings and functions
may now be modified:
(a) By adjusting this function, you can chose if
the entry code is shown on the display.
Press the key „1“ –
the entry code is shown on the display.
Press the key „0“ –
an entry code is not shown on the display,
instead the pressed keys will be shown on
the display as „ – “
(b) By adjusting this function you can set the
required length of the guest user code:
Press the key „3“ –
The user code must have 3 characters.
Press the key „4“ –
The user code must have 4 characters.
Press the key „5“ –
The user code must have 5 characters.
Press the key „6“ –
The user code must have 6 characters.
Press the key „7“ –
The user code must have 3 to 6
characters.
(c) By adjusting this function you can set the
lock out time used after a incorrect user code has
been entered four times:
Press the key „0“ –
There is no hold-off time after an incorrect
code has been entered four times.
Press the key „1“ –
There is a hold-off time of 15 minutes after
an incorrect code has been entered four
times.
Press the key „2“ –
There is a hold-off time of 30 minutes after
an incorrect code has been entered four
times.
(d) By adjusting this function you can decide if
the master code is activated or deactivated:
Press the key „2“ –
The master code is deactivated.
Press the key „3“ –
The master code is activated.
(e) By adjusting this function you can set that
both the opening and also the closing of the elec-
tronic lock is logged:
Press the key „0“ –
The opening of the electronic lock logged.
Press the key „1“ –
The opening as well as the closing of the
electronic lock logged.
07+8+9 GB Solution.15.9.14 _Layout 1 15.09.14 17:00 Seite 8