background image

1. GENERAL DESCRIPTION

The 

COMPUTHERM 

Q2RF 

plug was developed for the 

COMPUTHERM

 

Q3RF

Q5RF

Q7RF

 and 

Q8RF 

thermostats to increase their wireless range. 

The original range of 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostats is 50 m in 

open area, which can be significantly shortened by the structure of the building. 
To be able to use the 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostats in larger 

buildings too, it is advised to use a wireless signal repeater. This can be achieved by 
using the 

COMPUTHERM 

Q2RF

 wireless repeater: it receives the signals of the 

wireless thermostats and retransmits the signal to the receiver unit, thus making the 
range larger. The 

Q2RF 

plug should be connected to the mains voltage (230 V, 50 

Hz), meanwhile on the output of the 

Q2RF 

plug the 230 V, 50 Hz mains voltage also 

appears. The maximum load of the plug is be 16 A (3 A inductive).

2. PUTTING THE WIRELESS REPEATER INTO OPERATION

Warning! Modifying the socket can cause electric shock or product failure.

When choosing the location of the signal repeater unit you should remember that 
bulky metal objects (e.g. a boiler, buffer tank, etc.) and metal building structures 
may have an adverse effect on propagation of radio waves. If it is possible, in order 
to ensure trouble-free RF connection, we recommend that you install the receiving 
unit at a height of 1.5 to 2 m and at a distance of 1 to 2 m from the boiler or other 
bulky metal constructions. We recommend that you check reliability of RF connec-
tion at the place selected before installing the receiving unit.
Connect the 

COMPUTHERM

 

Q2RF

 wireless repeater plug to the mains voltage, 

approximately half way between the 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostat 

and Its receiver unit. After a couple of seconds the LEDs on the front panel of the 
plug flash once, after which the plug is ready for operation. Without tuning the de-
vice together with the thermostat or its receiver unit, it receives the signals from all 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostats in its range (the red LED flashes 3 

times), after which it transmits the signal to the receiver unit (the green LED flashes 
3 times) using the same security code. It causes absolutely no problems if there 
are more thermostats working in the range of the wireless repeater: as the security 
codes are kept for the repeated signals, an incorrect switch is not possible. 

3. FAST CHECK OF THE OPERATION OF THE WIRELESS 

REPEATER

It is easy to check the range of the 

Q3RF

Q5RF

Q7RF

 and 

Q8RF 

thermostats 

in a given environment by increasing the distance between the thermostat and the 
receiver unit. It is also simple to check the range expanding ability of the 

Q2RF 

 plug 

by connecting it to the mains voltage between the thermostat and the receiver unit 
when they are far away from each other.
Further, by pressing the „

TEST

” button, the verification of the operation of the 

Q2RF 

plug is easy, fast and can be done within one room by following the steps below:

a. 

Unplug the 

Q2RF

 device, in case it was plugged in before, and wait approx-

imately 1 minute to make sure that the capacitors inside the device are dis-
charged.

b.

 

Press and hold down the grey „

TEST

” button on the front side of the device, and 

meanwhile connect it to the mains voltage. Do not release the „

TEST

” button until 

the LEDs on the front side of the device first start flashing alternately, then after 
a couple of seconds they become continuously illuminated for approximately 2 
seconds together. After the  LEDs switch off (become unilluminated), the device 
is in „

TEST

” mode, and it is ready for the verification of its operation.

c.

 The „

TEST

” mode of the wireless repeater inverts the signal sent from the ther-

mostat to the receiver unit. When the thermostat sends a switch on command to 
the receiver unit and the sign of the heating/cooling equipment working appears 
on the display of the thermostat, the receiver unit turns on. A few seconds later 
the wireless repeater sends a switch off command to the receiver unit, so the re-
ceiver unit switches off. Similarly, a couple of seconds after the switch off signal 
of the thermostat, the wireless repeater  sends a switch on signal to the receiver 
unit.

  The inverted operation shows that the signal repeater plug is working properly. 

With the help of this „

TEST

” mode, it is easy and fast to check the proper oper-

ation of the 

Q2RF

 wireless repeater even if it is close to the thermostat and the 

receiver unit.

d.

 To finish using the „

TEST

” mode, unplug the device from the mains voltage and 

wait approximately 1 minute to make sure that the capacitors are discharged. Af-
ter this connect the device to the mains voltage again, and then it is ready to use. 

Reviews: