5.0 GAS FLOW SURGE
"P"
MEASUREMENT
5.1
Description
The GTFM has a peak value "sample and hold" feature. This allows the user to
measure the maximum gas flow rate, which occurred during the welding cycle. The
maximum value is the result of a gas surge, which occurs when the gas solenoid is
activated. The
"MODE"
switch on the front panel is used to display the maximum
flow rate. The maximum value is displayed by pressing the
"MODE"
switch to the up
position consecutively until the
"P"
parameter is displayed. The maximum value is
reset during power up and when the GTFM first detects gas flow.
8