background image

One-Way AM Remote R500A

By: Firstech, LLC. 

www.compustar.com

FCC ID :O44J1WENR

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including 

interference that may cause undesired operation.

CAUTION : Changes or modifications not expressly approved by 

the party responsible for compliance could void the 

user’s authority to operate this device.

USER’S GUIDE

One-Way AM Remote R500A / Alarm Controller CM1000A

By Firstech, LCC

www.compustar.com

Summary of Contents for CM1000A

Page 1: ...ay not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly appro...

Page 2: ...Doors Page 5 Arming and Disarming System Page 6 Trunk Release Page 6 Panic Mode Page 6 Valet Mode Page 7 Optional Programmable Features Ignition Controlled Door Locks Page 7 Passive Locking Page 8 St...

Page 3: ...triggering the Compustar alarm or operations Compustar systems could be frustrating to use for someone who is not familiar with them and who has no documentation available to reference for instructio...

Page 4: ...s flashing and the operation was not performed you will need to release the button and try again These operations will lock and unlock the doors as well Arming and Disarming the System To release the...

Page 5: ...or 1 siren chirp and 1 parking light flash 20 seconds after closing the last door 1 siren chirp and 1 parking light flash 30 seconds after closing the last door 1 siren chirp and 1 parking light flash...

Page 6: ...he vehicle will not sound during normal operations such as arm disarm lock unlock etc The siren will still sound if the alarm or Panic mode has been triggered To activate Mute mode tap the and buttons...

Page 7: ...ould be done on all wires even if you feel that you know exactly what they are and how they should test Use of a test light draws a considerable amount of current and may damage the electrical circuit...

Page 8: ...box The proper wire will test 12 volts positive when the parking light switch is in the on position Brown 12v Siren Output This wire will provide a 30 second positive output for the external siren Gr...

Page 9: ...ce you must fuse the connection Negative Trigger Door Lock System W O Actuator Positive Trigger Door Lock System W O Actuator External Actuator External Actuator No 1 Green 12v Ignition Input This wir...

Page 10: ...s wire monitors positive trigger door pins The proper wire will provide a positive trigger only when the doors are opened No 5 Violet Black Negative Trunk Trigger This input will monitor when the vehi...

Page 11: ...t respond to short lock unlock pulses 2 Application of Pre wired Kill Relay This option requires that the starter kill relay be installed in the ignition circuit rather than into the starter circuit W...

Page 12: ...s will flash once b The button for the optional setting The parking lights will flash twice 4 30 sec Passive Relock With this option enabled after disarming the system with the remote the system will...

Reviews: