
34
Setup Parameter
Values
Description
INTERFACE TYPE
parallel, serial, automatic,
auto+blink
Selects the interface type. In case of ‘automatic’ the interface
type is selected by the printer depending on data coming from
host. When the
auto+blink
item is selected, the P1 and P2
leds blink to indicate which interface is selected: P1 blinks
when the serial interface is selected, whereas P2 blinks, when
the parallel interface is selected.
INPUT BUFFER
1 Kb, 8 Kb, 16 Kb, 32 Kb
Selects the buffer size.
IGNORE PE
enabled, disabled
Selects whether the printer signals the paper empty condition
(
disabled
) or not (
enabled
).
AUTOFEED SIGNAL
disabled, enabled
The parallel interface uses (
enabled
) or does not use
(
disabled
) the AUTOFEED signal.
SLCT-IN SIGNAL
disabled, enabled
The parallel interface uses (
enabled
) or does not use
(
disabled
) the SELECT-IN signal.
BUFFER CONTROL
DTR, XON/XOFF,
XON/XOFF+DTR
Selection of the buffer protocol.
ROBUST XON
enabled, disabled
Perform the Robust XON (
enabled
) or not (
disabled
).
WORD LENGTH
7 bit, 8 bit
Sets the number of the data bits.
BAUD RATE
600 - 38400 bps
Sets the data transfer rate.
PARITY BIT
Even, odd, none
Selects the parity control for the data.
SECURITY MODE
enabled, disabled
Enables or disables the security actions that assure protection
against paper jams. If disabled, the paper handling is faster.