6 Product Overview
Digital I/O Connector Block
The digital inputs are normally used with security sensors, e.g. passive infrared sensors
(PIR), smoke detectors, etc. They work by detecting a change in the state of open and
closed circuit. The output ports are normally used to trigger external audio or visual in-
dicators, e.g. sirens or strobe lights, etc.
Pin
Function
Specifications
Note
Pinouts
1
Digital Input Port 1 (IN +)
M ax. 5V DC,
60mA
Floating, TTL
1 2 3 4 5 6 7 8 9 10
2
Digital Input Port 1 (IN –)
3
Digital Input Port 2 (IN +)
4
Digital Input Port 2 (IN –)
5
Digital Output Port 1 (NO)
Max. 2 4 V D C
, 1 A; or Max.
125V AC, 1A
You can only
u s e e i t h e r
the Normally
Open (NO) or
the Normally
Closed (NC) at
any given time
6
Digital Output Port 1 (COM)
7
Digital Output Port 1(NC )
8
Digital Output Port 2 (NO)
9
Digital Output Port 2 (COM)
10 Digital Output Port 2 (NC )
Schematic Connection Diagram
The following output scenario is where the siren will only sound when the input has
been triggered. Should you wish to use the other way around in which the output de-
vice keeps staying on until the input has been triggered, please use NC.