Factory default setting is 5 seconds.
1. Enter programming mode.
2. Enter 00 (this is a special code group), two "Di Di" sounds as
reminder.
3. Enter a desired lock/delay operation time in a two digits fomat
(01 to 99 seconds).
4. Press the button to quit.
.
.
.
.
.
1. Shut down the power of the unit and keep pressing the button .
2. Switch on the power pressing the button down, the unit will then
give a long continuous tone.
3. When the tone stoped, another sounds will be heard and input your
new 4 digits programmers codes.
1. Press the button plus your 4 digits master codes
2. Your are successfully enter the programming mode when three
sounds is heard and the LED is flashing.
3. Press the button to quit.
1. Enter programming mode.
2. It is available for 40 groups code. 01 to 40 is the group number,
which should be input in front of the 4 digits codes from 31 to 40
group codes, input once 4 digits codes to open the door for a long
time until twice the same code to have it closed.
3. Input 4 digits codes, a two sounds is heard, it is unsuccessful and
indicating the code is existent at somewhere, if a three sounds is
heard, it is successfully set.
4. Press the button to quit.
.
.
.
.
.
1. The original factory defaulted programming
password is 1234.
2. Input a 4 digits password to have the door
striked or the lock unlocked.
Change the master code
Entering programming mode
Set the unlocking time
Add user codes
Camera lens
Power
Working electric current
Illumination
Communication duration
Communication method
Working temperature
IP rating
DC 14.5V
200mA
1/3 CCD 72 degree ken
0.05 LUX
120s
Duplex communication type
55
o
-20
+55 C
Specifications of 50/561 series code access