In the setting mode:
Enter one set number(3 digits) from 000 to 999 data storage units,
yellow LED indicator will be flashing:
1. If red LED indicator is on, means there is data stored in this set of unit,
press the button twice to clean up;
2. If green LED indicator is on, means this number data storage unit can
be added card and passwords in.
Add card and passwords steps:
1. Enter in setting mode, and the yellow LED indicator will be flashing.
2. Input three-figure from 000 to 999 data storage units, and the green
LED indicator lighting.
3. Swipe card, and a sound "BI" means added in. Then input the correlative
passwords(correlative for the card just added in this data storage unit).
The length of passwords should be the same as admin code. For
example, the admin code is 12 (two is the length), herein should
setting two digits passwords, you can set 00-99 as your passwords.
If the admin code is 123 (three is the l ength), h erein s hould s etting
t h
ree d igits p asswords, you can s
et 0
00-999 a
s y
our p
asswords. T
he
rest may be deduced by analogy
……
After the sound "BI", means
card added in and passwords setting successfully.
Press the button to quit setting mode.
Add the user card and code(ZONE 1)
Set the length of passwords
In the setting mode:
Press the button and yellow LED indicator will be flashing, then
press the button and a sound "BI" as reminder, then input X(X=2,3,4,
5,6):
2--Stands for the password/code digit length is 2(00-99)
3--Stands for the password/code digit length is 3(000-999)
The rest may be deduced by analogy, and the maximum is 6.
A sound "BI" as reminder, means digit length setting s
uccessfully. If the
sound is "BI BI BI", means digit length is as same as the existence, and new
setting is not permitted.
Press the button to quit setting mode.
4
NOTICE
Once the digit length changed, all added
cards and passwords will be cleared.
-18-
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
input two-figure from 00 to 09 data storage units, yellow LED indicator will
be flashing;
there is data stored in
this set of unit.
it means this number data storage
unit can be added card or password in.
Press the button to quit the setting mode.
1. But if red LED indicator light is on, it means
storage unit existed data, press the button twice to clean up;
2. If green LED indicator light is on,
Add card or passwords steps:
Swipe card, and a sound "BI" means added in; O
R in put t he c orrelative
passwords (correlative for the card just added in this data storage unit)
the length of passwords should be as same as admin code. For
example, the admin code is 12 ( two is the length ), herein should
setting two digits passwords, you can set 00-99 as your password.
The admin code is 123(three is the length), herein should setting three
digits passwords, you can set 000-999 as your passwords. The rest
may be deduced by analogy...... After the sound "BI", means card
added in or passwords setting successfully.
Add the user card or code(ZONE 2)
In the setting mode:
Enter one set number(3 digits) from 000 to 999 data storage units,
if red LED indicator is on, means there is data stored in this set of unit, press
the button twice to delete the card and code.
Delete the user card and code(ZONE 1)
Delete the user card or code(ZONE 2)
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
input two-figure from 00 to 09 data storage units, i
there is data stored in this set of unit,
f red LED indicator light
is on, it means
press the button
twice to delete the card or code.