If you do not have Compaq Insight Manager, use the following procedure:
■
Drive Failure indicator
Check the drive tray indicators for a Drive Failure indication. See
Figure 5-2. These are visible through the lens in the front bezel. If the
Drive Failure indicator on one of the drive trays is illuminated, that
drive has failed.
WARNING:
To reduce the risk of personal injury from hot metallic
surfaces, handle the drives only by the plastic latches.
Open the front bezel and replace the failed drive. If your operating system or
SMART Controller supports hot-pluggable drives, do not turn off power to the
unit. Refer to "Removing and Replacing Hot-Pluggable Drives" in Chapter 4.
CAUTION:
Remove a drive only if the drive tray
Drive Failure
indicator is
ON and the
Drive Access
and
On-Line
indicators are OFF. Failure to
observe these indicator conditions when replacing a failed drive in a fault-
tolerant configuration may result in loss of data.
Drive Failure
5-2.EPS
Figure 5-2.
Drive Failure Indicator