Removal and Replacement Procedures
Refer to “Integrated ATA RAID Configuration Utility” later in this chapter for information
on the utility menu options.
If there is not an online spare configured:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Reconfigure the array, choosing one of the following options:
c. Run the rebuild in the Integrated ATA RAID Configuration Utility (F8).
d. Let the auto-rebuild take place when the operating system is up and running
RAID 0+1 Configurations
In a RAID 0+1 situation, multiple drive failures can be handled as long as both elements of a
mirror have not failed.
To rebuild the array:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Reconfigure the array, choosing one of the following options:
a. Run the rebuild in the Integrated ATA RAID Configuration Utility by pressing the
F8 key.
b. Let the auto-rebuild take place when the operating system is up and running
Refer to “Integrated ATA RAID Configuration Utility” later in this chapter for information
on the utility menu options.
Integrated ATA RAID Configuration Utility
The setup screen of the Integrated ATA RAID Configuration Utility has three menu
windows:
•
•
•
Array Information
Physical Drive Information
Help Information
Array Information
IMPORTANT: You cannot add drives or remove drives from an array that has been already configured.
Compaq ProLiant ML330 Generation 2 Server Maintenance and Service Guide
2-21
COMPAQ CONFIDENTIAL Codename: Mimic/Reaper Part Number: 234832-003 Last Saved On: 11/25/02 10:18 AM
Summary of Contents for 234664-002 - ProLiant - ML330T02