AEROHEAT SHOWER OWNERS MANUAL
TROUBLESHOOTING
This guide should be followed in case of failure of the
appliance to operate correctly.
If symptoms persist contact Customer Service on
1300 362 921.
Do not attempt to repair or modify the appliance.
ABNORMAL OPERATION
Unit will not operate
Check that appliance is switched on
Check thre outlet hose & fitting are
correctly connected to the appliance
Check that fuse is not blown
Check that adequate DC power is available
Check DC fuse in cigarette lighter fitting
Unit will not switch on
- display will not
illuminate
Check DC fuse in cigarette lighter fitting
Check that adequate AC/DC power is
available
Check if battery requires recharging
Burner will not light
Check that gas cylinder is turned on and
that there is gas in cylinder
Check that outlet hose & fitting are
correctly connected
Check there are no error messages on
the display
Turn fan speed down
Check there is sufficient gas
Air is too hot
Turn fan up to MAX
Turn burner off & only operate fan
ERROR CODES
The appliance is fitted with a number of operational and
safety features that can be identified by the following
error codes. In the event that the unit will not operate
refer to the Troubleshooting Guide:
E1:
Outlet hose fitting not connected or not connected
correctly
E2:
Tilt switch activated – place on level surface and
re-start appliance
E3:
No flame / burner not lit – Check gas cylinder &
connections
E6:
Over temperature shut off – Once activated this will
take at least 5 minutes to cool down - the only way to
restart is to wait 5 minutes & turn off/on then attempt
restart
Appliance cutting out due to air temperature
too hot:
If
E6 Over temperature shut off
.
1.
Allow heater to cool down for approximately 5 minutes
to clear over temp error
Try using heater again - If overtemp error appears again
it may be too warm to use the heater, the unit is only
suitable for use in ambient temperatures under 15˚c