Manufacturer Contact Details

 

Manufacturer Contact  

Details 

The Compac AdBlue Dispenser is designed and 
manufactured by: 

Compac Industries Limited 
52 Walls Road, Penrose, Auckland 1061, New Zealand 
P.O. Box 12-417, Penrose, Auckland 1641, New Zealand 

Phone: + 64 9 579 2094 
Fax: + 64 9 579 0635 

www.compac.co.nz 
Copyright ©2014 Compac Industries Limited, All Rights 
Reserved 

 
Contact your service agent in the first instance for any installation issues. 
 

26. 

Revision History 

Previous revision date

 

Summary of changes

 

11 March 2014 (new) 

Changed LLA 30-160SQ footprint to MK2 version, added LA 30-
160SD footprint. 

08 May 2014 

Added LLA30-80S footprint, amended LLA30S(same end), LLA30-
160S & LLA30-160SQ, LA30S, LLA30S (opposite end) footprints. 

26 June 2014 

Added sump info in accordance with EPA. File ref. COM 09 29 

29 August  

Added LA30-40SD LA30-80SD LA30-160SD LLA30-40S LLA30-
40SQ LLA30-80S footprints. 

 

 

 

 

 

 

 

Summary of Contents for Laser AdBlue LA 30-160SD

Page 1: ...l Laser AdBlue Dispenser Version LA 30S LLA 30S AdBlue duo LLA 30S AdBlue duo nozzles on same end LLA 30 40S AdBlue diesel duo LA 30 40SD AdBlue diesel lane specific LLA 30 40SQ AdBlue diesel quad LLA...

Page 2: ...p switch settings 13 10 1 Standard Pump Comms Setting 13 10 2 Gilbarco Pump comms Setting 13 11 Triac Dip switches 13 12 Electrical Operation Test 14 13 Mechanical Commissioning and Air Purge 15 14 Se...

Page 3: ...has no control over each installation s unique operating environment Hence Compac Industries Limited makes no representations or warranties concerning the performance of the unit under the actual ope...

Page 4: ...transit in particular damage to electronics due to vibration or jarring All terminals and plugs should be checked including IC chips to ensure they are securely in place 4 AdBlue pump specifications E...

Page 5: ...Where local regulations for flammable substances require a sump to be fitted a Sumps must be provided at all dispenser installations with secondary containment pipework and at all new installations an...

Page 6: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 6 of 23 7 Footprints 7 1 LLA 30S two hose with nozzles on opposite ends...

Page 7: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 7 of 23 7 2 LLA 30S Duo two hose with nozzles on same end...

Page 8: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 8 of 23 7 3 LA 30S...

Page 9: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 9 of 23 7 4 LA30 40SD LA30 80SD LLA30 40S LLA30 80S...

Page 10: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 10 of 23 7 5 LA 30 160SD LLA 30 160S...

Page 11: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 11 of 23 7 6 LLA 30 40SQ LLA30 80SQ LLA30 160SQ...

Page 12: ...s Electrical cables are terminated at the C4000 Power Supply which is housed in the Flameproof Enclosure located in the bottom of the dispenser behind the door The incoming cables are terminated as sh...

Page 13: ...3 ON 4 OFF These are factory set to the standard setting unless ordered otherwise eg Gilbarco 10 2 Gilbarco Pump comms Setting Special software and interface board required 1 OFF 2 ON 3 OFF 4 ON 11 T...

Page 14: ...olenoids will energise starting the pump motor Check that Diodes D8 D10 and D11 turn on indicating a signal is being sent to the triacs to open the solenoid valves 8 The diagnostic LED D18 flashes qui...

Page 15: ...transaction and continue delivering AdBlue 9 Repeat steps 4 through 6 until the AdBlue flows without any air being present then hang the nozzle 10 Remove the dummy encoder plug and re install the V40...

Page 16: ...ose For a single hose only Pn will appear 14 3 2 Setting the Price Using the Parameter Switch follow the chart to set the price for the hose s in question Step ACTION RESULT 1 Ensure that the nozzle i...

Page 17: ...14 Not used J3 Input from meter side A J9 Power for meters J15 Not used J4 Input from meter side B J10 Totes J16 Not used J5 Not used J11 Buzzer J17 Backlighting J6 Not used J12 Nozzle Switches Connec...

Page 18: ...ser into a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information ab...

Page 19: ...n on again For unattended refuelling sites the dispensers should not be able to work in stand alone mode in the event of a controller failure Therefore the dispenser should be set up to inhibit standa...

Page 20: ...Laser Installation Sheet doc Page 20 of 23 18 2 ZVA AdBlue Nozzle The ZVA AdBlue nozzle with a magnetic safety catch is commonly used on AdBlue dispensers The following image is included for reference...

Page 21: ...ioner Although generators are fitted with power regulators most are not filtered sufficiently for powering sensitive electrical components We recommend installing a commercial power conditioner and or...

Page 22: ...ice agent contact details Use this information when contacting service agent or help desk Model number Serial number Date of manufacture Date of installation Software version Equipment connected to th...

Page 23: ...co nz Copyright 2014 Compac Industries Limited All Rights Reserved Contact your service agent in the first instance for any installation issues 26 Revision History Previous revision date Summary of ch...

Reviews: