5/5 2005.04.22
Maintenance.
Change oil first time after 100 hours of operation. Subsequent changes of oil are required after every
3000 hours of operation.
Change of oil:
1.
Drain off oil removing the oil plug under the oil tank.
2.
Clean the oil tank after the oil has been drained off.
3.
Fill with hydraulic oil up to the marking on the test prod
4.
Bleeding: Operate the piston to max. Stroke and return fully. Repeat this 4 – 5 times.
Oil quantity: 30 liter.
Decommissioning:
If the press should ever be scrapped, drain off the oil into an approved container and dispose it at an
approved authority.
Oil Company Type
Castrol
Hyspin AWHM 46
Statoil
Hydraway HVXA 46
BP
BARTRAN HV 46
Shell
TELLUS 46
AGIP OSO
46