INS_FDX4D_REV–
08/23/10
PAGE 5
TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL
FDX4D(M)(S)(-M)
FIGURE 6 – LED INDICATORS
LINK
DATA ACTIVITY (1 – 4)
POWER
GREEN
Unit In Sync
Activity
Unit Powered Up
RED
Unit Not In Sync
No Activity
–
OFF
No Optical Link
–
Unit Powered Down
FIGURE 5 – DATA SETTINGS
RS232
Customer
Equipment
FDX4D
Customer
Equipment
FDX4D
RS422
Bi-phase or
Manchester
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
Data Out (+)
Data Out (–)
2-Wire
RS485,
Sensornet
DIN(+)
DIN(–)
DIN(+)
DIN(–)
Data (A)
Data (B)
Data Transmit
Data Receive
Signal Ground
DIN(–)
DOUT(–)
GND
DOUT(–)
DIN(–)
GND
4-Wire
RS485
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
Data Out (+)
Data Out (–)
Data In (+)
Data In (–)
Data In (+)
Data In (–)
Data (A)
Data (B)
Data Receive
Data Transmit
Signal Ground
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
Data In (+)
Data In (–)
Data Out (+)
Data Out (–)