background image

 INS_CWGE26FX2TX24MSPOE_REV–     5 Mar 2014     PAGE 47

INSTALLATION AND OPERATION MANUAL 

CWGE26FX2TX24MSPOE

TECH SUPPORT: 1.888.678.9427

VLAN

VLAN Membership Configuration

The VLAN membership configuration for the selected stack switch unit switch can be monitored 
and modified here. Up to 64 VLANs are supported. This page allows for adding and deleting 
VLANs as well as adding and deleting port members of each VLAN.

Label

Description

Delete

Check to delete the entry. It will be deleted during the next save.

VLAN ID

The VLAN ID for the entry.

MAC Address

The MAC address for the entry.

Port Members

Check marks indicate which ports are members of the entry. Check or uncheck as 
needed to modify the entry.

Adding a New 
Static Entry

Click 

Add New VLAN 

to add a new VLAN ID. An empty row is added to the table, and 

the VLAN can be configured as needed. Legal values for a VLAN ID are 1 through 
4095. 
The VLAN is enabled on the selected stack switch unit when you click on 

Save

. The 

VLAN is thereafter present on the other stack switch units, but with no port members. 
A VLAN without any port members on any stack unit will be deleted when you click 

Save

The 

Delete 

button can be used to undo the addition of new VLANs.

Summary of Contents for CWGE26FX2TX24MSPOE

Page 1: ...of which are also gigabit combo ports supporting 100 1000FX SFP Modules A further two 100 1000FX SFP ports are also included Up to 400 watts of PoE power is available for distribution across all 24 el...

Page 2: ...6 Software Features 7 Hardware Features 8 Hardware Overview 9 Front Panel 9 Rear Panel 10 Rack mount kit assembly 10 Ethernet Cables 11 1000 100BASE TX 10BASE T Pin Assignments 11 SFP 13 Console Cabl...

Page 3: ...2 SNMP 57 Traffic Prioritization 63 Multicast 77 Security 81 AAA 85 RADIUS Overview 87 Warning 98 System Warning 99 Monitor and Diag 101 Port Statistic 104 System Log Information 107 Cable Diagnostics...

Page 4: ...INS_CWGE26FX2TX24MSPOE_REV 5 Mar 2014 PAGE 4 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427...

Page 5: ...and markets the next generation of video solutions for the CCTV defense and homeland security markets At the core of ComNet s solutions are a variety of high end video servers and the ComNet IVS softw...

Page 6: ...PSE ports and 2x100 1000Base X SFP ports supports Ethernet Redundancy protocol C Ring recovery time 30ms over 250 units of connection and MSTP RSTP STP compatible It can protect your mission critical...

Page 7: ...hronization Provides HTTPS SSH protocol to enhance network security IP based bandwidth management application based QoS management Device Binding security function IGMP v2 v3 IGMP snooping support for...

Page 8: ...678 9427 Hardware Features 450 Watts power supply included Operating Temperature 10 to 60 C Storage Temperature 40 to 85 C Operating Humidity 5 to 95 non condensing 22 10 100 1000Base T X 2 100 1000Ba...

Page 9: ...connecter to manage switch 2 8 7 5 6 1 3 4 CWGE26FX2TX24MSPOE 1 Console port DB 9 Female connector 2 10 100 1000Base T X Gigabit Ethernet ports 3 LED for Odd Numbered Ethernet ports Link Act status 4...

Page 10: ...TECH SUPPORT 1 888 678 9427 Rear Panel 1 2 The rear panel of CWGE26FX2TX24MSPOE 1 Power Switch 2 Power input for AC 100V 240V 50 60Hz Rack mount kit assembly You can find the rack mount kit and the sc...

Page 11: ...pe Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 ohm UTP UTP 100 m 328ft RJ 45 1000 100BASE TX...

Page 12: ...Assignment 1 BI_DA 2 BI_DA 3 BI_DB 4 BI_DC 5 BI_DC 6 BI_DB 7 BI_DD 8 BI_DD The CWGE26FX2TX24MSPOE Series switches support auto MDI MDI X operation You can use a straight through cable to connect PC to...

Page 13: ...e Switch has fiber optical ports with SFP connectors The fiber optical ports are in multi mode 0 to 550M 850 nm with 50 125 m 62 5 125 m fiber and single mode with LC connector Please remember that th...

Page 14: ...from DCE Device 2 Received Data Received by DTE Device Transmitted Data Transmitted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Tran...

Page 15: ...ed management features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports In...

Page 16: ...T 1 888 678 9427 System Login 1 Launch Internet Explorer 2 Type http and the IP address of the switch Press Enter 3 The login screen appears Login screen 4 Key in the username and password The default...

Page 17: ...INS_CWGE26FX2TX24MSPOE_REV 5 Mar 2014 PAGE 17 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Main Interface Main interface...

Page 18: ...The first character must be an alpha character And the first or last character must not be a minus sign The allowed string length is 0 to 255 System Description The device Description System Location...

Page 19: ...em password required to access the web pages or log in from CLI Label Description Old Password Enter the current system password If this is incorrect the new password will not be set New Password The...

Page 20: ...d can be set to one of the following values none authentication is disabled and login is not possible local use the local user database on the switch for authentication radius use a remote RADIUS serv...

Page 21: ...ddress Assign the IP address that the network is using If DHCP client function is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch an...

Page 22: ...web browser to an HTTP connection Possible modes are Enabled Enable HTTPS mode operation Disabled Disable HTTPS mode operation Save Click to save changes Reset Click to undo any changes made locally a...

Page 23: ...user to inspect and configure the current LLDP port settings Label Description Port The switch port number of the logical LLDP port Mode Select LLDP mode Disabled The switch will not send out LLDP inf...

Page 24: ...ised by the neighbor unit Port Description Port Description is the port description advertised by the neighbor unit System Capabilities System Capabilities describes the neighbor unit s capabilities T...

Page 25: ...ers Label Description Neighbor entries were last changed at Shows the time for when the last entry was last deleted or added It is also shows the time elapsed since last change was detected Total Neig...

Page 26: ...ained within the table Entries are removed from the table when a given port links down an LLDP shutdown frame is received or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple...

Page 27: ...uration You can save view or load the switch configuration The configuration file is in XML format with a hierarchy of tags Firmware Update This page facilitates an update of the firmware controlling...

Page 28: ...tion is activated the system will collect the DHCP client information and display in here DHCP Client List You can assign the specific IP address which is in the assigned dynamic IP range to the speci...

Page 29: ...ort to 10Mbps full duplex mode 100Mbps HDX Force the Cu port to 100Mbps half duplex mode 100Mbps FDX Force the Cu port to 100Mbps full duplex mode 1Gbps FDX Force the Cu port to 1Gbps full duplex mode...

Page 30: ...lumn allows for changing the power savings mode parameters per port Disabled All power savings mechanisms disabled ActiPHY Link down power savings enabled PerfectReach Link up power savings enabled En...

Page 31: ...ddress is enabled Destination MAC Address The Destination MAC Address can be used to calculate the destination port for the frame Check to enable the use of the Destination MAC Address or uncheck to d...

Page 32: ...w Group ID Normal indicates there is no aggregation Only one group ID is valid per port Port Members Each switch port is listed for each group ID Select a radio button to include a port in an aggregat...

Page 33: ...he port from the aggregation By default no ports belong to any aggregation group Only full duplex ports can join an aggregation and ports must be in the same speed in each group Key The Key value incu...

Page 34: ...he id is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID...

Page 35: ...port link is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled Key The key assigned to this port Only port...

Page 36: ...switch port number LACP Transmitted Shows how many LACP frames have been sent from each port LACP Received Shows how many LACP frames have been received at each port Discarded Shows how many unknown...

Page 37: ...primary port when this switch is Ring Master 2nd Ring Port The backup port when this switch is Ring Master Coupling Ring Mark to enable Coupling Ring Coupling Ring can be used to divide a big ring in...

Page 38: ...The maximum age of the information transmitted by the Bridge when it is the Root Bridge Valid values are in the range 6 to 40 seconds and MaxAge must be FwdDelay 1 2 Maximum Hop Count This defines th...

Page 39: ...order to share spanning trees for MSTI s Intra region The name is at most 32 characters Configuration Revision The revision of the MSTI configuration named above This must be an integer between 0 and...

Page 40: ...sibly change them as well Label Description MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numerical values have better pr...

Page 41: ...d to control priority of ports having identical port cost See above OpenEdge state flag Operational flag describing whether the port is connecting directly to edge devices No Bridges attached Transiti...

Page 42: ...a network administrator to prevent bridges external to a core region of the network causing address flushing in that region possibly because those bridges are not under the full control of the adminis...

Page 43: ...settings are stack global Label Description Port The switch port number of the corresponding STP CIST and MSTI port Path Cost Controls the path cost incurred by the port The Auto setting will set the...

Page 44: ...s Bridge ID The Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently assigned the root port role Root Cost Root Path Cost Fo...

Page 45: ...e logical STP port CIST Role The current STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort State The current STP port sta...

Page 46: ...ion BPDU s received transmitted on the port STP The number of legacy STP Configuration BPDU s received transmitted on the port TCN The number of legacy Topology Change Notification BPDU s received tra...

Page 47: ...VLAN ID The VLAN ID for the entry MAC Address The MAC address for the entry Port Members Check marks indicate which ports are members of the entry Check or uncheck as needed to modify the entry Adding...

Page 48: ...INS_CWGE26FX2TX24MSPOE_REV 5 Mar 2014 PAGE 48 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 VLAN Port Configuration...

Page 49: ...mes untagged frames received on the port are discarded By default the field is set to All Port VLAN Mode Configures the Port VLAN Mode The allowed values are None or Specific This parameter affects VL...

Page 50: ...rame obtain a tag based on PVID and is forwarded When the port received tagged frames 1 If a tagged frame with TPID 0x8100 it is forwarded 2 If the TPID of tagged frame is not 0x8100 ex 0x88A8 it will...

Page 51: ...TPID 8100 Packet VID 5 TPID 8100 VID PVID TPID 8100 Packet VID 5 TPID 88A8 Packet Discarded QinQ S custom port is used for user defined TPID If the Ethertype for Custom S ports is configured to 8123...

Page 52: ...N Access Mode Setting P7 P7 P2 P2 P1 P1 P8 P8 CWGE26FX2TX24MSPOE Switch A CWGE26FX2TX24MSPOE Switch B CWGE26FX2TX24MSPOE Switch C VLAN Trunk 10 20 VLAN 10 VLAN 10 VLAN 20 VLAN 20 VLAN Trunk 10 20 In t...

Page 53: ...runk mode P7 P7 P2 P2 P1 P1 P8 P8 CWGE26FX2TX24MSPOE Switch A CWGE26FX2TX24MSPOE Switch B CWGE26FX2TX24MSPOE Switch C VLAN Trunk 10 20 VLAN 10 VLAN 10 VLAN 20 VLAN 20 VLAN Trunk 10 20 In the topology...

Page 54: ...10 20 Configure the VLAN for the Switch as shown VLAN QinQ mode Below is an example of the VLAN QinQ Mode which is typically used in an environment with unknown VLAN VLAN X Unknown VLAN P2 P2 P1 P1 P...

Page 55: ...MSPOE_REV 5 Mar 2014 PAGE 55 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 VLAN Management VLAN ID Setting If Management VLAN is set only the same VLAN ID port can c...

Page 56: ...ion Delete Check to delete the entry It will be deleted during the next save Private VLAN ID Indicates the ID of this particular private VLAN Port Members A row of check boxes for each port is display...

Page 57: ...et SNMP supported version 1 SNMP v2c Set SNMP supported version 2c SNMP v3 Set SNMP supported version 3 Read Community Indicates the community read access string to permit access to SNMP agent The all...

Page 58: ...ported version 3 Trap Community Indicates the community access string when send SNMP trap packet The allowed string length is 0 to 255 and the allowed content is the ASCII characters from 33 to 126 Tr...

Page 59: ...raps and informs is needed When Trap Probe Security Engine ID is enabled the ID will be probed automatically Otherwise the ID specified in this field is used The string must contain an even number bet...

Page 60: ...security model that this entry should belong to Possible security models are NoAuth NoPriv None authentication and none privacy Auth NoPriv Authentication and none privacy Auth Priv Authentication an...

Page 61: ...ame A string identifying the security name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is the ASCII characters from 33 to 126 Group Name A string iden...

Page 62: ...ted during the next save Group Name A string identifying the group name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is the ASCII characters from 33 to...

Page 63: ...packets per second The configuration indicates the permitted packet rate for unicast multicast or broadcast traffic across the switch Note Frames which are sent to the CPU of the switch are always lim...

Page 64: ...zero has the lowest priority If the port is VLAN aware and the frame is tagged then the frame is classified to a QoS class that is based on the PCP value in the tag as shown below Otherwise the frame...

Page 65: ...mes are classified to a PCP value If the port is VLAN aware and the frame is tagged then the frame is classified to the PCP value in the tag Otherwise the frame is classified to the default PCP value...

Page 66: ...of QoS Egress Port Tag Remarking for all switch ports Label Description Port The logical port for the settings contained in the same row Click on the port number in order to configure tag remarking M...

Page 67: ...In Ingress settings you can change ingress translation and classification settings for individual ports There are two configuration parameters available in Ingress 1 Translate 2 Classify 1 Translate T...

Page 68: ...apped DSCP value is either taken from the DSCP Translation Egress Remap DP0 table or from the DSCP Translation Egress Remap DP1 table Port Policing This page allows you to configure the Policer settin...

Page 69: ...to 100 1000000 when the Unit is kbps and it is restricted to 1 3300 when the Unit is Mbps This field is only shown if at least one of the queue policers are enabled Unit Controls the unit of measure...

Page 70: ...actual queue shaper rate e g 800 Mbps Qn Shows disabled or actual port shaper rate e g 800 Mbps DSCP Based QoS This page allows you to configure the basic QoS DSCP based QoS Ingress Classification set...

Page 71: ...g the DSCP for QoS class and DPL map There are two configuration parameters for DSCP Translation 1 Translate 2 Classify 1 Translate DSCP at Ingress side can be translated to any of 0 63 DSCP values 2...

Page 72: ...E26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 DSCP Classification This page allows you to configure the mapping of QoS class and Drop Precedence Level to DSCP value Label Description QoS Class Actual Qo...

Page 73: ...ID can be any value in the range 1 4095 or Any user can enter either a specific value or a range of VIDs PCP Priority Code Point Valid value PCP are specific 0 1 2 3 4 5 6 7 or range 0 1 2 3 4 5 6 7...

Page 74: ...oint value DSCP It can be a specific value range of values or Any DSCP values are in the range 0 63 including BE CS1 CS7 EF or AF11 AF43 IP Fragment Ipv4 frame fragmented option yes no any Sport Sourc...

Page 75: ...888 678 9427 QoS Counters This page provides statistics for the different queues for all switch ports Label Description Port The logical port for the settings contained in the same row Qn There are 8...

Page 76: ...ames IPv6 The QCE will match only IPV6 frames Port Indicates the list of ports configured with the QCE Action Indicates the classification action taken on ingress frame if parameters configured are ma...

Page 77: ...Enabled Enable the Global IGMP Snooping Unregistered IPMCv4Flooding enabled Enable unregistered IPMC traffic flooding Router Port Specify which ports act as router ports A router port is a port on the...

Page 78: ...ields allow the user to select the starting point in the VLAN Table Clicking the Refresh button will update the displayed table starting from that or the next closest VLAN Table match The will use the...

Page 79: ...he Querier status is ACTIVE or IDLE Querier Receive The number of Transmitted Querier V1 Reports Receive The number of Received V1 Reports V2 Reports Receive The number of Received V2 Reports V3 Repor...

Page 80: ...SUPPORT 1 888 678 9427 IGMP Snooping Groups Information Entries in the IGMP Group Table are shown on this page The IGMP Group Table is sorted first by VLAN ID and then by group Label Description VLAN...

Page 81: ...iter to apply to this port The allowed values are Disabled or the values 1 through 15 The default value is Disabled Port Copy Select which port frames are copied to The allowed values are Disabled or...

Page 82: ...miters Configure the rate limiter for the ACL of the switch Label Description Rate Limiter ID The rate limiter ID for the settings contained in the same row Rate The rate unit is packet per second pps...

Page 83: ...ype for this ACE These frame types are mutually exclusive Any Any frame can match this ACE Ethernet Type Only Ethernet Type frames can match this ACE The IEEE 802 3 specifies the value of Length Type...

Page 84: ...for the ACE Counter The counter indicates the number of times the ACE was hit by a frame Label Description VLAN ID Filter Specify the VLAN ID filter for this ACE Any No VLAN ID filter is specified VL...

Page 85: ...reliable by design In order to cope with lost frames the timeout interval is divided into 3 subintervals of equal length If a reply is not received within the subinterval the request is transmitted ag...

Page 86: ...entication Server If the port is set to 0 zero the default port 1812 is used on the RADIUS Authentication Server Secret The secret up to 29 characters long shared between the RADIUS Authentication Ser...

Page 87: ...f this server Status The current status of the server This field takes one of the following values Disabled The server is disabled Not Ready The server is enabled but IP communication is not yet up an...

Page 88: ...s up and running and the RADIUS module is ready to accept accounting attempts Dead X seconds left Accounting attempts were made to this server but it did not reply within the configured timeout The se...

Page 89: ...WGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Label Description Packet Counters RADIUS authentication server packet counter There are seven receive and four transmit counters Other Info This section c...

Page 90: ...ON MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Label Description Packet Counters RADIUS accounting server packet counter There are five receive and four transmit counters Other Info This sec...

Page 91: ...erver are RADIUS packets RADIUS packets also encapsulate EAP PDUs together with other attributes like the switch s IP address name and the supplicant s port number on the switch EAP is very flexible i...

Page 92: ...e RADIUS server must be configured accordingly When authentication is complete the RADIUS server sends a success or failure indication which in turn causes the switch to open up or block traffic for t...

Page 93: ...Period This setting applies to the following modes i e modes using the Port Security functionality to secure MAC addresses MAC Based Auth When the NAS module uses the Port Security module to secure MA...

Page 94: ...valid credentials within a certain amount of time another supplicant will get a chance Once a supplicant is successfully authenticated only that supplicant will be allowed access This is the most secu...

Page 95: ...effect Reauthenticate Schedules a reauthentication whenever the quiet period of the port runs out EAPOL based authentication For MAC based authentication reauthentication will be attempted immediately...

Page 96: ...tatistics for a specific switch port running port based authentication For MAC based ports it shows selected backend server RADIUS Authentication Server statistics only Use the port select box to sele...

Page 97: ...ckend Server Counters These backend RADIUS frame counters are available for the following administrative states 802 1X MAC based Auth Last Supplicant Client Info Information about the last supplicant...

Page 98: ...98 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Warning Fault Alarm When any selected fault event is happened the Fault LED in switch panel will light up and the e...

Page 99: ...mode operation When the mode operation is enabled the syslog message will send out to syslog server The syslog protocol is based on UDP communication and received on UDP port 514 and the syslog serve...

Page 100: ...cannot be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface The following table describes the labels in this screen Label Description System Cold Start Alert when syste...

Page 101: ...eouts for entries in the dynamic MAC Table and configure the static MAC table here Aging Configuration By default dynamic entries are removed from the MAC after 300 seconds This removal is also called...

Page 102: ...Table before changing to secure learning mode otherwise the management link is lost and can only be restored by using another non secure port or by connecting to the switch via the serial interface S...

Page 103: ...e starting point in the MAC Table Clicking the Refresh button will update the displayed table starting from that or the closest next MAC Table match In addition the two input fields will upon a Refres...

Page 104: ...received and transmitted packets per port Bytes The number of received and transmitted bytes per port Errors The number of frames received in error and the number of incomplete transmissions per port...

Page 105: ...ackets Rx and Tx Multicast The number of received and transmitted good and bad multicast packets Rx and Tx Broadcast The number of received and transmitted good and bad broadcast packets Rx and Tx Pau...

Page 106: ...ess or destination mirroring Port to mirror also known as the mirror port Frames from ports that have either source rx or destination tx mirroring enabled are mirrored to this port Disabled disables m...

Page 107: ...Error level of the system log All All levels Time The time of the system log entry Message The MAC Address of this switch Auto Refresh Check this box to enable an automatic refresh of the page at regu...

Page 108: ...the page refreshes automatically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports wil...

Page 109: ...STALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 SFP Monitor DDM function can pass SFP module which supports DDM function measure the temperature of the apparatus and man...

Page 110: ...cally until responses to all packets are received or until a timeout occurs PING6 server 10 10 132 20 64 bytes from 10 10 132 20 icmp_seq 0 time 0ms 64 bytes from 10 10 132 20 icmp_seq 1 time 0ms 64 b...

Page 111: ...the 1 pps clock output 2 Input Enable the 1 pps clock input 3 Disable Disable the 1 pps clock in out put External Enable This Selection box will allow you to configure the External Clock output The fo...

Page 112: ...wo step Sync events and Pdelay_Resp events are used Clock Identity It shows unique clock identifier One Way If true one way measurements are used This parameter applies only to a slave In one way mode...

Page 113: ...f power that each port may reserve The allocated reserved power for each port PD is specified in the Maximum Power fields 2 Class mode In this mode each port automatically determines how much power to...

Page 114: ...upport backup power supply only the primary power supply settings will be shown In case that the primary power source fails the backup power source will take over For being able to determine the amoun...

Page 115: ...unt of power the switch has allocated for the PD Power Used The Power Used shows how much power the PD currently is using Current Used The Power Used shows how much current the PD currently is using P...

Page 116: ...configuration is retained Label Description Yes Click to reset the configuration to Factory Defaults No Click to return to the Port State page without resetting the configuration System Reboot You ca...

Page 117: ...pports CLI management You can use console or telnet to management the switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before Configuring by RS 232 serial console use an DB 9...

Page 118: ...S_CWGE26FX2TX24MSPOE_REV 5 Mar 2014 PAGE 118 INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Step 2 Input a name for new connection Step 3 Select to use COM port numbe...

Page 119: ...88 678 9427 Step 4 The COM port properties setting 115200 for baud rate 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the ke...

Page 120: ...IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address...

Page 121: ...2TX24MSPOE TECH SUPPORT 1 888 678 9427 Commander Groups System System Configuration all port_list Reboot Restore Default keep_ip Contact contact Name name Location location Description description Pas...

Page 122: ...st enable disable Mode port_list auto 10hdx 10fdx 100hdx 100fdx 1000fdx sfp_auto_ams Flow Control port_list enable disable MaxFrame port_list max_frame Power port_list enable disable actiphy dynamic E...

Page 123: ...eCustomSport etype Add vid name ports_list Forbidden Add vid name port_list Delete vid name Forbidden Delete vid name Forbidden Lookup vid name name Lookup vid name name combined static nas all Name A...

Page 124: ...cal radius enable disable Security Switch SSH Security switch ssh Configuration Mode enable disable Security Switch HTTPS Security switch ssh Configuration Mode enable disable Security Switch RMON Sec...

Page 125: ...t DHCP Dynamic Host Configuration Protocol Security Network Psec Security Network Psec Switch port_list Port port_list Security Network NAS Security Network NAS Configuration port_list Mode enable dis...

Page 126: ...icmp_type icmp_code ip_flags udp sip dip sport dport ip_flags tcp sip dip sport dport ip_flags tcp_flags permit deny rate_limiter port_redirect mirror logging shutdown Delete ace_id Lookup ace_id Cle...

Page 127: ...sti clear Msti Add msti vid Port Configuration port_list Port Mode port_list enable disable Port Edge port_list enable disable Port AutoEdge port_list enable disable Port P2P port_list enable disable...

Page 128: ...ort_list PoE PoE Configuration port_list Mode port_list disabled poe poe Priority port_list low high critical Mgmt_mode class_con class_res al_con al_res lldp_res lldp_con Maximum_Power port_list port...

Page 129: ...dd qce_id qce_id_next port_list tag vid pcp dei smac dmac_type etype etype LLC DSAP SSAP control SNAP PID ipv4 protocol sip dscp fragment sport dport ipv6 protocol sip_v6 dscp sport dport class dp cla...

Page 130: ...port_copy logging shutdown Policy port_list policy Rate rate_limiter_list packet_rate Add ace_id ace_id_next switch port port policy policy vid tag_prio dmac_type etype etype smac dmac arp sip dip sm...

Page 131: ...ommunity Add community ip_addr ip_mask Community Delete index Community Lookup index User Add engineid user_name MD5 SHA auth_password DES priv_password User Delete index User Changekey engineid user_...

Page 132: ...PortDataSet clockinst port_list announceintv announceto syncintv delaymech minpdelayreqintv delayasymmetry ingressLatency LocalClock clockinst update show ratio clockratio Filter clockinst def_delay_f...

Page 133: ...Fault Alarm PortLinkDown port_list enable disable Alarm PowerFailure pwr1 pwr2 pwr3 enable disable Event Event Configuration Syslog SystemStart enable disable Syslog PowerStatus enable disable Syslog...

Page 134: ...CWGE26FX2TX24MSPOE TECH SUPPORT 1 888 678 9427 Ring Ring Mode enable disable Master enable disable 1stRingPort port 2ndRingPort port Couple Mode enable disable Couple Port port Dualhoming Mode enable...

Page 135: ...z for 1000Base X IEEE 802 3x for Flow control IEEE 802 3ad for LACP Link Aggregation Control Protocol IEEE 802 1p for COS Class of Service IEEE 802 1Q for VLAN Tagging IEEE 802 1w for RSTP Rapid Spann...

Page 136: ...nhance network security Web and CLI authentication and authorization Authorization 15 levels IP source guard Software Features IEEE 1588v2 clock synchronization IEEE 802 1D Bridge auto MAC address lea...

Page 137: ...00Base T X RJ45 Port Green for Link Act indicator 100 1000Base X SFP Port Green for port Link Act PoE Green PoE enabled LED 24 Fault contact Relay None Power Power Input 100 240VAC with power socket P...

Page 138: ...ORPORATE DRIVE DANBURY CT 06810 USA T 203 796 5300 F 203 796 5303 TECH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 2...