background image

IN1SFP Series   10/18/14   PAGE 3

Multimode or Single Mode, 
1 or 2 Optical Fibers  
(SFP Dependent)

CAT5/6

CAT5/6

LINK LED 

(See Fig 5)

STATUS LED 

(See Fig 5)

POWER LED 

(See Fig 5)

Black
Black With White Stripe
Power Supply:
Surface Mount:  
22 to 27 VAC or 8 to 24 VDC

FIGURE 3 – Mini CNMC2+1SFP/M

FIGURE 4 – Mini CNMC2+1SFP/M

INSTALLATION AND OPERATION MANUAL 

CNMC2+1SFP[/M]

REAR PANEL

FRONT PANEL

TECH SUPPORT: 1.888.678.9427

DIP Switches

(See Fig 6)

Summary of Contents for CNMC2+1SFP

Page 1: ...ection of sold separately SFP optical module The ComNet exclusive Demux feature allows for port isolation replicating two media converters over one fiber The ComNet exclusive Mux feature prevents network video flooding of multicast traffic with DIP switch selection of the fiber port as a dedicated uplink path The CNMC2 1SFP series can be powered by wide range of AC or DC input power supplies LED i...

Page 2: ...SFP Dependent FIGURE 2 Standard Mount CNMC2 1SFP FIGURE 1 Standard Mount CNMC2 1SFP REAR PANEL FRONT PANEL LEDs See Fig 5 CAT5 6 CAT5 6 Black Black With White Stripe Power Supply Rack Mount From Rack Surface Mount 8 to 24 VDC NOTE Remove Electrical Connector for Rack Mount Units Fault Relay 0 36V 190mA AC or DC Normally Closed See Fig 10 DIP Switches See Fig 6 ...

Page 3: ...NK LED See Fig 5 STATUS LED See Fig 5 POWER LED See Fig 5 Black Black With White Stripe Power Supply Surface Mount 22 to 27 VAC or 8 to 24 VDC FIGURE 3 Mini CNMC2 1SFP M FIGURE 4 Mini CNMC2 1SFP M INSTALLATION AND OPERATION MANUAL CNMC2 1SFP M REAR PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 DIP Switches See Fig 6 ...

Page 4: ...y functioningliketwoseparatemediaconvertersoveronefiber 6 100 1000 1000 MBPS Unitmustberestartedfora speedchangetotakeeffect 100MBPS Unitmustberestartedforaspeedchangetotakeeffect INSTALLATION AND OPERATION MANUAL CNMC2 1SFP M TECH SUPPORT 1 888 678 9427 FIGURE 7 DIP Switches CNMC2 1SFP M Small Size Units Only FIGURE 8 Fault Relay Operation CNMC2 1SFP Standard Size Units Only The fault relay is no...

Page 5: ...l go only to Port 1 and traffic from Port 2 will go only to Port 2 only functioning like two separate media converters over one fiber INSTALLATION AND OPERATION MANUAL CNMC2 1SFP M TECH SUPPORT 1 888 678 9427 Port 1 Multicast traffic Port 1 Multicast traffic Port 2 Multicast traffic Port 2 Multicast traffic Port 1 All traffic Port 1 Port 1 Traffic Port 1 All traffic Port 1 Port 1 Traffic Port 2 Al...

Page 6: ... rack 1 Make sure that the card is oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the...

Reviews: