FCC Marking

This Equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instruction manual, may cause harmful interference to radio 
communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received; including interference that may cause undesired operation.

CE Marking

This equipment complies with the requirements relating to electromagnetic compatibility, EN 
55022 class A for ITE, the essential protection requirement of Council Directive 2004/108/EC on 
the approximation of the laws of the Member States relating to electromagnetic compatibility.
Company has an on-going policy of upgrading its products and it may be possible that 
information in this document is not up-to-date. Please check with your local distributors for the 
latest information. No part of this document can be copied or reproduced in any form without 
written consent from the company.

Trademarks

All trade names and trademarks are the properties of their respective companies.

Summary of Contents for CNGE1IPS-95

Page 1: ...asily combined on one cable eliminating the need to install additional power outlets and electrical cabling The CNGE1IPS95 is fully compliant with the requirements of IEEE 802 3at for Power Sourcing Equipment PSE and features auto detection of powered devices PDs Transmission distances of up to 330 feet 100 meters are supported and this injector supplies operating power for all PDs drawing a maxim...

Page 2: ...AGE 2 INSTALLATION AND OPERATION MANUAL CNGE1IPS 95 TECH SUPPORT 1 888 678 9427 Contents FCC Marking 3 CE Marking 3 Trademarks 3 Introduction 4 Installation package 5 Power connection 6 Specifications 8 Housing Dimensions mm 9 ...

Page 3: ... expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Marking This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE ...

Page 4: ...IN Rail or wall mounted and can tolerate 40 C to 75 C in harsh environment to perform a reliable network NOTE Always make sure the total length of the TX cable DOES NOT exceed 100 meters Total length is defined as length A length B Length A Length B 100 meter During 100Mbps transmission the maximum total cable length is 100 meter POE signal attenuates every meter the built in transformer allows th...

Page 5: ... 18 PAGE 5 INSTALLATION AND OPERATION MANUAL CNGE1IPS 95 TECH SUPPORT 1 888 678 9427 Installation package The following items are shipped with this device DIN Rail Bracket Wall Mount Plates 2 Screws 4 4 pin Terminal Block ...

Page 6: ...round Connect positive wire to V connect negative wire to V and also connect neutral wire to ground V1 is for power input 1 connection V2 is for power input 2 connection this unit supports two power inputs Connecting procedure Step 1 Take out 4 pin terminal block located in the included mounting kit package Step 2 Connect power wire to V1 or V2 with correct polarity Step 3 Plug into terminal block...

Page 7: ...S 95 TECH SUPPORT 1 888 678 9427 LED Indicators LED Signal Definition PoE Solid PoE is active Off PoE is inactive Flashing PoE is detecting PW1 On Power 1 is connected Off No power detected at Power 1 input PW2 On Power 2 is connected Off No power detected at Power 2 input ...

Page 8: ...ment Pin 1 V 2 V 3 V 6 V Pin 4 V 5 V 7 V 8 V Reverse polarity protection Present Overload current protection Present Power Supply 2 Redundant power source 48V 56V VDC Power Input Power Consumption 1 W 48 VDC Without PoE POE power Maximum PoE power 95 watts at 56 VDC input Removable Terminal Block Provide 4 pin terminal block Wire range 0 34mm2 to 2 5mm2 Solid wire AWG 12 24 14 22 Stranded wire AWG...

Page 9: ...Certifications EN55022 24 ITE equipment EN55011 Industrial Scientific and Medical ISM equipment Safety IEC EN60950 1 EMC EMS CE FCC VCCI EMI FCC Part 15 Subpart B Class A CE EN 55022 Class A Vibration EN 50155 EN 60068 2 6 Shock EN 50155 EN 60068 2 27 Free Fall EN 50155 EN 60068 2 32 Housing Dimensions mm ...

Page 10: ...cations Networks Corporation All Rights Reserved ComNet and the ComNet Logo are registered trademarks of Communication Networks LLC 3 CORPORATE DRIVE DANBURY CT 06810 USA T 203 796 5300 F 203 796 5303 TECH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET ...