background image

INSTALLATION AND OPERATION MANUAL 

CNFE3FX1TX2C[/M] Series

CONTACT OVER ETHERNET MODULES

The ComNet CNFE3FX1TX2C[/M] series is an industrially hardened three-port 
intelligent switch with light management functionality and an integrated contact 
closure server. The 100BASE-FX port supports conventional CAT-5e/CAT-6 copper or 
optical transmission media by selection of the appropriate ComNet SFP* module. A 
summary fault alarm provides indication via a form c relay in the event of loss of optical 
link or operating power. The 10/100BASE-TX ports support both auto-negotiation and 
automatic MDI/MDI-X crossover for full and half-duplex operation; manual MDI/
MDI-X switching is not required. The integrated contact closure server is available 
with 4 or 8 channels and supports individual user selectable wet or dry inputs. Form 
A relay outputs feature individual user selection of normally open or normally closed 
operation via the built-in web GUI. The contact server supports 4 modes of operation 
including one-to-one, one-to-many, many-to-one and stand-alone.

The internal/self-contained 9 to 36 VDC or 24 VAC power supply features 
redundant power inputs, for the highest possible reliability. The simple to install, 
CNFE3FX1TX2C/M Series is DIN-rail or panel-mountable, and is ideal for mission-
critical applications where very high levels of reliability and network availability are of 
the utmost importance.

This manual serves the following 

ComNet Model Numbers:

CNFE3FX1TX2C8TX
CNFE3FX1TX2C8RX
CNFE3FX1TX2C4DX
CNFE3FX1TX2C8TX/M
CNFE3FX1TX2C8RX/M
CNFE3FX1TX2C4DX/M

Summary of Contents for CNFE3FX1TX2C4DX

Page 1: ...he integrated contact closure server is available with 4 or 8 channels and supports individual user selectable wet or dry inputs Form A relay outputs feature individual user selection of normally open or normally closed operation via the built in web GUI The contact server supports 4 modes of operation including one to one one to many many to one and stand alone The internal self contained 9 to 36...

Page 2: ...witch Port Configuration 13 Active Ping Check Configuration 14 Authentication Username and Password Configuration 15 Firmware Upgrade 16 Factory Defaults 17 System Reset 18 Network Interface Configuration 19 SMNP 20 SNMP Config 20 Alarm Contact 21 In Contact Ethernet Link 22 Out Contact Ethernet Link 23 Contact Status 24 Contact Configuration 24 Static Multicast Routing Per Port 25 Static MAC Lock...

Page 3: ...al link or operating power The 10 100BASE TX ports support both auto negotiation and automatic MDI MDI X crossover for full and half duplex operation manual MDI MDI X switching is not required The integrated contact closure server is available with 4 or 8 channels and supports individual user selectable wet or dry inputs Form A relay outputs feature individual user selection of normally open or no...

Page 4: ...ting Temperature 40 75ºC Storage Temperature 40 85ºC Operating Humidity 5 95 non condensing 2 10 100Base T X Fast Ethernet port 1 100 Base X SFP 4 Dry Contact Inputs 4 Form A Relays 1 Form A Alarm Relay USB Console Port 115 2K baud 8N1 Dimensions Mini units w wall mount adapter plate 5 4 2 7 2 9 in 13 7 6 7 7 4 cm Mini units w DIN rail mount clips 3 9 2 7 3 6 in 9 9 6 7 9 1 cm ...

Page 5: ...LLATION AND OPERATION MANUAL CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Mechanical Drawing of ComFit CNFE3FX1TX2C MODULE including contact connector pin out Mechanical Drawing of Mini CNFE3FX1TX2C M MODULE including contact connector pin out ...

Page 6: ...tus Description PWR1 Green On DC Power Input 1 Good Off No power detected PWR2 Green On DC Power Input 2 Good Off No power detected STATUS Green On Initialization passed Red On Failed 10 100Base T X Ethernet ports LNK ACT Green On Port link up Blinking Data transmitting 100 Mbps indicator Amber On Port speed is 100 Mbps SFP LNK ACT Green On Port link up Blinking Data transmitted ...

Page 7: ...ification by SNMP trap and Alarm Relay Output Web based GUI and USB Console CLI configuration Enable disable ports IGMPv3 Multicast host Static MAC lock per port Static multicast MAC routing Field firmware upgrade capable Port Guardian physical port lockout feature Active ping check with SNMP trap port shutdown capability Port Statistics Remote Reset Factory default reset ...

Page 8: ...ubs Please refer to the following table for cable specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100Ω UTP 100m 328ft RJ 45 100BASE TX Cat 5 100Ω UTP UTP 100m 328ft RJ 45 1000BASE TX Cat 5 Cat 5e 100Ω UTP UTP 100m 328ft RJ 45 10 100BASE T X Pin Assignments With 100BASE T X 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 a...

Page 9: ...u can connect them to a PC with USB Ports using the supplied USB to USB Mini B male plug cable SFP The CNFE3FX1TX2C4DX has a fiber optic port that utilizes an SFP connector ComNet offers a wide selection of SFP modules that offer different fiber type connector type and distances Please remember that the TX port of Switch A should be connected to the RX port of Switch B Application Examples One to ...

Page 10: ... management features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explorer 5 0 or later Preparing for Web Management The default value is as below IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Sy...

Page 11: ...INS_CNFE3FX1TX2C M Series 10 11 11 PAGE 11 INSTALLATION AND OPERATION MANUAL CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Main Index page ...

Page 12: ...3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 System Information The switch system information is provided here Label Description Enabled protocols Summary table of enabled protocols Temperature Unit s internal board temperature reading Port link status Link status and port disable ...

Page 13: ... CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Switch Port Configuration Unless you have reason to change this setting it is recommended to leave the negotiation set to auto The link segment requires forcing the settings Both ends of the link need to have the same selection ...

Page 14: ...l perform the action selected in the Failure Action menu Label Description Enable Select to enable the active ping check function Interval Active ping check interval in seconds Remote IP Configure IP addresses of remote device to ping Failure action Configure action to take upon failure No Action No action taken SNMP Trap Issue an SNMP trap Power Down Turn off the RJ45 port PwrDwn Trap Issue an SN...

Page 15: ...eries 10 11 11 PAGE 15 INSTALLATION AND OPERATION MANUAL CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Authentication Username and Password Configuration The username and password entered here are also used in the CLI ...

Page 16: ...s on how to upload the new image is located in Firmware Upgrade section After applying a new firmware version it is recommended that a Factory Default Reset is performed to ensure that all new or adjusted settings take effect Please note that performing a Factory Default reset will erase all the devices settings except for the IP address Warning Do not enable the firmware update process unless you...

Page 17: ... MANUAL CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Factory Defaults This function restores the system configuration back to the factory default values All parameters will revert back to the original factory default values except the network configuration settings ...

Page 18: ...7 System Reset This feature will perform a system reset Some system configuration changes require a system reset to take effect File System updates Network configuration changes Static Mac Lock changes Static Mcast routing After a system reset there may be a delay of up to 15 seconds before the device becomes responsive again ...

Page 19: ...s from the network DHCP server The default IP address will be replaced by the IP address which the DHCP server has assigned IP Address Assign the IP address that the switch will use If DHCP client Function is enabled you do not need to assign the IP address Gateway Assign the network gateway for the switch Subnet MaskPrimary DNS Assign the subnet mask for the switch Primary DNS Assign the primary ...

Page 20: ...ork problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP SNMP Config Label Description SNMP V1 V2c Community The switch supports one Read and one Write SNMP community string Community string names are limited to 8 characters To disable a community string leave its entry blank SNMP trap enable E...

Page 21: ... allows for the setting of what happens when specific instances occur during the operation of the unit allowing for the triggering of the alarm contact CNFE3FX1TX2C4DX Contact Override allows for the override and force setting of the alarm contact for testing and troubleshooting purposes CNFE3FX1TX2C4DX Contact Status shows the current status of the output of the alarm contact ...

Page 22: ...e for the Port Number As well as enabling the One to One option the desired input contacts must be selected from the Selected Input Contacts section One to Many Enabling this option allows for the use of multicasting the contacts between a group of devices within the same multicast group For this work the Multicast Group and Port Number must match the same Multicast Group and Port Number as the Ou...

Page 23: ...on the Remote Output IP must match the IP Address of the device you wish to communicate with This is also true for the Port Number One to Many Enabling this option allows for the use of multicasting the contacts between a group of devices within the same multicast group For this work the Multicast Group and Port Number must match the same Multicast Group and Port Number as the Input Contact Config...

Page 24: ...2C M Series TECH SUPPORT 1 888 678 9427 Contact Status Allows for a display of the current overview of the current states for the input and output contacts Contact Configuration Contact Configuration allows for the configuration of each port for both input and output to trigger SMNP Traps ...

Page 25: ...outing Per Port Label Description Enable Enable static multicast MAC routing MAC Addr Destination Multicast MAC address of the stream Port Number Ports to be included in the multicast route Apply Select Apply to activate the configurations Help Show help file Note A system reset must be performed after making changes to the MAC routing settings ...

Page 26: ...e static MAC locking MAC Addr MAC address of the device that is allowed to forward and receive traffic Packets will be dropped for MAC addresses not listed in the table stream Port Number Ports to be included in the locked list Apply Select Apply to activate the configurations Help Show help file Note A system reset must be performed after making changes to the static MAC lock settings ...

Page 27: ...ink loss status is detected when a cable is disconnected This provides high security against network attack by an intruder who accesses the edge device and disconnects it to then try and connect their own intrusion device laptop network sniffer etc To reset a port from a lock out state the network administrator can issue an SNMP reset or can reset a port by using the CLI via the USB serial port In...

Page 28: ...X1TX2C M Series TECH SUPPORT 1 888 678 9427 Port Guardian CLI Reset Command Description portguardian show Will display any ports that are currently in port lockout fault state Command Description portguardian clear Will clear any ports that were previously in port lockout fault state ...

Page 29: ...twork configuration You can use USB console to manage the switch by CLI CLI Management by USB Console 115200 8 none 1 none Before configuring by USB console use a USB mini B cable to connect the switch s Console port to your PC s USB port Follow the steps below to access the console via USB mini B cable Step 1 Connect the USB cable between the PC and the CNGE4 2SMS If the device driver is not foun...

Page 30: ...LATION AND OPERATION MANUAL CNFE3FX1TX2C M Series TECH SUPPORT 1 888 678 9427 Step 3 Select the COM port number Step 4 The COM port properties setting 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control ...

Page 31: ...PORT 1 888 678 9427 Step 5 Hit enter to initiate the connection and receive the username prompt After entering the username and password the console will be presented with a CLI prompt Enter or help to list the commands More detailed help for each command is available using help in front of the command name ...

Page 32: ...the web server and open the FileSystem Upload page click the Enable Image upload check box and hit apply 2 Open the Windows bootloader application click the enable Ethernet check box and adjust the IP address to the target IP 3 Click the Load Hex File and select the new firmware file Click Erase Click Program Click Verify Click run application Note The Erase Program Verify button is not supported ...

Page 33: ...ECH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS ComNet Customer Service Customer Care is ComNet Technology s global service center where our professional staff is ready to answer your questions at any time Email ComNet Global Service Center custom...