background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power up 

 

Continues beep for 3 seconds 

 

Power failure 

 

Beeps every 30 seconds 

 

 

30 seconds WARNING Beep before the unit cuts off 
the battery voltage 

 

LED Indication 

 

RED 

 

GREEN 

 

BUZZER  For no buzzer 

Battery charging 

 

OFF 

 

ON 

 

OFF 

 

Remove link 

Battery fully charged 

OFF 

 

ON 

 

OFF 

 

Remove link 

No Mains, battery 
voltage ok 

 

 

 

 

No Mains Battery 
voltage below 10.5V 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring diagram 

 

Link open – 
Buzzer activated. 
Link joined ‐ 
Buzzer not 

activated 

 

 

 

 

 

 

 

AC Fail. 

 (Positive) for a AC fail condition 
When AC is restored goes 0V (Negative) 

Negative 12V 

DC Output (‐12V) 

Black 

Positive 12V 

DC Output (+12V) 

Red 

Positive 12V 

DC +12V 

Negative 12V 

DC 0V DC 

Connecting 

 

Before connecting the battery, plug the unit into mains. 

 

Disconnect mains before wiring up the equipment to the unit 

 

The unit will dissipate a small amount of heat so please ensure that the unit is installed in a 

place where there is sufficient ventilation. 

 

This unit must not be installed outside as it is not protected against water. 

Operation 

Audible Tone 

Warranty 

 

This product carries a one year warranty and is subject to the proper installation procedures 

and must be installed by a qualified person. 

Standards 

 

Complies with EN55022, EN61000‐3‐2, 3, EN55024, SANS IEC 60 950 

Battery cut off 

FLASHING 

OFF 

ON 

Remove link 

FLASHING 

ON 

Remove link 