Power up
Continues beep for 3 seconds
Power failure
Beeps every 30 seconds
30 seconds WARNING Beep before the unit cuts off
the battery voltage
LED Indication
RED
GREEN
BUZZER For no buzzer
Battery charging
OFF
ON
OFF
Remove link
Battery fully charged
OFF
ON
OFF
Remove link
No Mains, battery
voltage ok
No Mains Battery
voltage below 10.5V
Wiring diagram
Link open –
Buzzer activated.
Link joined ‐
Buzzer not
activated
AC Fail.
(Positive) for a AC fail condition
When AC is restored goes 0V (Negative)
Negative 12V
DC Output (‐12V)
Black
Positive 12V
DC Output (+12V)
Red
Positive 12V
DC +12V
Negative 12V
DC 0V DC
Connecting
Before connecting the battery, plug the unit into mains.
Disconnect mains before wiring up the equipment to the unit
The unit will dissipate a small amount of heat so please ensure that the unit is installed in a
place where there is sufficient ventilation.
This unit must not be installed outside as it is not protected against water.
Operation
Audible Tone
Warranty
This product carries a one year warranty and is subject to the proper installation procedures
and must be installed by a qualified person.
Standards
Complies with EN55022, EN61000‐3‐2, 3, EN55024, SANS IEC 60 950
Battery cut off
FLASHING
OFF
ON
Remove link
FLASHING
ON
Remove link