background image

860508548 
Instruction Sheet 

 

www.commscope.com 

 

 

Orange pair

Blue pair

Green pair

Brown pair

Ensure that front pairs

are tightly routed

 

6.  (T568B wiring shown) On the 

Reverse

 cable end, pull Green and Brown pairs back, eliminate the twist, and 

pull them tightly into place.  Then route Orange and Blue pairs to the front positions. 

Note:  For T568A Wiring

 - 

On each cable end, one of the two pairs fed in through the holes is pulled back for the rear positions.  Check 
label color codes. 

 

Conductor Seating and Cutting 

Impact tool on HI setting
with M110 cutting blade

Hand puck

Pliers

Trim pairs
flush

Fine edge
cutters

 

1.  Use impact tool on HI setting with M110 

cutting blade to punch conductors 
straight down into slots.  When using the 
impact tool, the hand puck is 
recommended. 

Or 

2.  Use pliers with wire cap to seat 

conductors.  Use fine edge cutters to 
trim conductors flush to the module 
body. 

 

Page 4 of 5 

Summary of Contents for UNJ10G

Page 1: ...427 Replacement 110 blade for D 914 impact tool 760122713 Module removal tool quantity of 5 860333673 Hand termination tool hand puck 405423260 KS 22035 L2 spudger tool How to Contact Us To find out more about CommScope products visit us on the web at http www commscope com For technical assistance Within the United States contact your local account representative or technical support at 1 800 344...

Page 2: ...until the jacket is snug against the rear housing Outer pairs should sweep around the inside pairs and not be pulled into them Direct Cable End Reverse Cable End Orange pair Green pair Brown pair Blue pair Brown pair Orange pair Green pair Blue pair 1 Each cable end has two pairs routed into the holes and two pairs routed over the top without crossover or rearrangement On the Direct cable end the ...

Page 3: ...ir in a counter clockwise direction enough to open it up 4 Push conductors down into slot positions check color codes Maintain pair twist up to the opening for the slots Orange pair Blue pair Green pair Brown pair Ensure that front pairs are tightly routed 5 T568B wiring shown On the Direct cable end place Orange and Blue pairs first then place Green and Brown pairs Page 3 of 5 ...

Page 4: ... On each cable end one of the two pairs fed in through the holes is pulled back for the rear positions Check label color codes Conductor Seating and Cutting Impact tool on HI setting with M110 cutting blade Hand puck Pliers Trim pairs flush Fine edge cutters 1 Use impact tool on HI setting with M110 cutting blade to punch conductors straight down into slots When using the impact tool the hand puck...

Page 5: ...es of module and press firmly 2 The module can then be removed from the back Inspection or Repair of Termination Note To enable inspection or repair the wiring cap can be released from the module using the removal tool A spudger tool can then be used to remove conductors for repair 1 Insert end of removal tool into slot under wiring cap and pivot it forward to release cap Removal tool Insert end o...