1-Port 5Gb PoE Extender Manual
Rev A
21
5. Detailed Specifications
Table 4.4 and provides a partial listing of the maximum supported hybrid cable distances for a
range of NEC Class 2 power supply output voltages, hybrid cable copper gauges, and extender
output power levels. NEC Class 2 requires a power supply unit (PSU) limited to less than 60V DC.
In practice, some commercial 48V power supplies may be configured to output from 48V up to
about 57V. Pout is the maximum total PoE Extender output power
*Assumptions:
Hybrid cable temp: 20C (Underground/Ducted).
Table 4.1: Maximum Hybrid Fiber Cable Lengths*
PSU Output
Voltage
Cable
Gauge
(AWG)
Max Cable
Length (m)
Pout = 60W
Max Cable
Length (m)
Pout = 45.4W
Max Cable
Length (m)
Pout = 30.8W
Max Cable
Length (m)
Pout = 30W
Max Cable
Length (m)
Pout = 15.4W
Maximum
(57V)
12
650
1120
1570
1595
2630
16
255
445
620
630
1040
Nominal (48V)
12
460
795
1100
1120
1840
16
180
315
435
440
725
Minimum
(40.5V)
12
330
555
770
780
1285
16
130
220
305
310
510
Table 4.2: Part Numbers
Version
Catalogue Number
60W 5Gb 1-Port Poe Extender
PFU-P-E-060-01
Table 4.3: Climatic Performance
Item
Specification
Storage Temperature
-40
º
C to +70
º
C
Installation Temperature
-5
º
C to +45
º
C
Operating Temperature
-40
º
C to +65
º
C
65°C assumes 45°C ambient air temperature, plus 20°C sun loading.
Summary of Contents for PFU-P-E-O-060-01
Page 1: ...860659348 Rev A 1 Port 5Gb PoE Extender Manual 860659348 Rev A October 2020 ...
Page 2: ......
Page 6: ...1 Port 5Gb PoE Extender Manual 2 ...
Page 8: ...1 Port 5Gb PoE Extender Manual 4 ...
Page 12: ...1 Port 5Gb PoE Extender Manual 8 ...
Page 14: ...1 Port 5Gb PoE Extender Manual 10 ...