background image

Two Port PoE Extender Hardware Manual

This product is copyright © 2017 CommScope, LLC. All Rights Reserved.

29

Attaching an Earth Point

Attach your earth connection to the earth point below.

Operating Temperature Advice

At the top of the Two Port PoE Extender’s operating temperature range, the physical temperature of 
the PoE Extender may exceed 70ºC. Ensure the supplied solar shield is in place for protection. See 
Table 4.2 on page 31 for operating temperature details.

Summary of Contents for PFU-P-C-O-060-02

Page 1: ...860634349 Two Port PoE Extender Hardware Manual ...

Page 2: ......

Page 3: ...ents 11 Two Port PoE Extender 11 Part Number 11 In the Box 11 Also Required Not Included 12 3 Installation 13 Remove Heat Shield 13 Remove Seal Caps and Grommets 13 Connect Ethernet Cables 15 Splitting the Powered Fiber Cable 16 Cable Split Dimensions 17 SFP Relationship to Ethernet ports 20 Setting the SFP Connection Speed 21 Connecting the Powered Fiber Cable to the PoE Extender 22 Connecting th...

Page 4: ...Two Port PoE Extender Hardware Manual 4 This product is copyright 2017 CommScope LLC All Rights Reserved ...

Page 5: ...ed in the equipment installation manual all data and control ports are connected to ES1 SELV NEC Class 2 conformant circuits inside the enclosure To maintain all the ports on the equipment at SELV NEC Class 2 it is essential that if any connection is made to any of these ports by other equipment the other equipment must maintain its relevant port at ES1 SELV NEC Class 2 For products that are rack ...

Page 6: ... there are no user serviceable parts inside this equipment 11 If this equipment has a laser observe the precautions stated in the installation manual 12 Ultimate disposal of this equipment must be carried out according to relevant national laws 13 The equipment should be installed by suitably trained personnel and installation should follow good working practice ...

Page 7: ...ensemble des données et ports de contrôle sont raccordés à des circuits conformes à la de classe 2 SELV NEC ES1 à l intérieur de l enceinte Pour maintenir tous les ports de l équipement en classe 2 SELV NEC ES1 il est indispensable qu en cas de raccordement établi vers l un quelconque de ces ports par tout autre équipement ce dernier puisse maintenir son port correspondant en classe 2 SELV NEC ES1...

Page 8: ...ceptible de réparation par l utilisateur de l équipement 11 Si cet équipement comporte un dispositif laser veuillez respecter les précautions indiquées à cet égard dans le guide d installation 12 La suppression définitive de cet équipement devra être effectuée conformément aux lois nationales pertinentes 13 L équipement doit être installé par du personnel parfaitement qualifié et l installation de...

Page 9: ...nstallationshandbuch nicht ausdrücklich anders vermerkt sind alle Datenschnittstellen und Steueranschlüsse mit ES1 SELV NEC Class 2 konformen Schaltkreisen im Inneren des Gehäuses verbunden Damit alle Ports des Geräts mit ES1 SELV NEC Class 2 konform bleiben ist es wichtig dass die Ports verbundener Geräte ebenfalls ES1 SELV NEC Class 2 entsprechen Für Geräte die in einem Rack montiert werden 6 Be...

Page 10: ... keine zu wartenden Teile 11 Wenn dieses Gerät mit einem Laser ausgestattet ist beachten Sie die in der Installationsanleitung angegebenen Vorsichtsmaßnahmen 12 Die Entsorgung dieses Geräts muss nach den einschlägigen nationalen Rechtsvorschriften erfolgen 13 Das Gerät muss durch entsprechend geschultes Personal installiert werden Bei der Installation ist auf gute Arbeitspraxis zu achten ...

Page 11: ...en tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la class B est conforme a la norme ICES 003 du Canada ...

Page 12: ...mScope LLC All Rights Reserved Return Product Procedure If the unit is found to be defective please contact Technical Support via www commscope com SupportCenter TechnicalSupport aspx Product user Guide This document details the physical features of the Two Port PoE Extender ...

Page 13: ...EC Class II and SELV standards eliminating the need for qualified electricians during installation The PoE Extender also contains circuit protection and DC DC conversion electronics which automatically condition electrical voltage to the correct level needed for PoE input to the device under load such as a small cell high definition security camera Wi Fi hot spot etc Why Protect Remotely Powered C...

Page 14: ...on elements include Cross polarity protection to simplify installation the circuit will work regardless of the input polarity AC cross protection 4A non replaceable fuses No exposed high voltage pads High power inductors used as coordinating elements to maximize energy efficiency Sealed enclosure for environmental protection ...

Page 15: ...ht 2017 CommScope LLC All Rights Reserved 11 2 Package Contents Two Port PoE Extender Part Number The part number for the Two Port PoE Extender is PFU P C O 060 02 In the Box The PoE Extender is supplied ready for cable installation with the solar shield attached ...

Page 16: ...ase X or1000Base X SFP transceiver Singlemode or Multimode 25mm Torque or adjustable spanner wrench 30mm Torque or adjustable spanner wrench Posidriv screwdriver Silicone grease Loctite 222 Knife for splitting the fiber cable 12 AWG or 2mm diameter wire stripper for 12 AWG cable 16 AWG or 1 2mm wire diameter stripper for the 16 AWG cable Fastenings for wall pole mounting ...

Page 17: ...t Shield Remove the 4 bolts attaching the heat shield to the PoE Extender with a 3mm Allen key Slide the heat shield off the retaining lugs and put to one side Remove Seal Caps and Grommets Unscrew the caps and then remove the grommets from the 3 pass through connectors Note Do not unscrew any of the pass throughs from the PoE Extender These have been factory fitted and sealed to the correct torqu...

Page 18: ...Two Port PoE Extender Hardware Manual 14 This product is copyright 2017 CommScope LLC All Rights Reserved ...

Page 19: ...d the seal cap and ethernet grommet on to the cable as below 5 Connect one of the RJ45 to the PoE Extender to the left hand pass through with the lock clip facing upwards as below Note the Ethernet cable is still loose in the grommet Note Connection from the PoE Extender to the Customer s equipment should be via a Cat 5E Cat 6 screened STP cable Note If using a pre terminated ethernet cable it may...

Page 20: ... Splitting the Powered Fiber Cable The CommScope Powered Fiber Cable consists of 2 copper power threads and a third containing the fiber threads You need to separate the three cores to allow the power to be connected to the screw terminals and the fiber thread to be connected to a fiber terminal which is then inserted in to the SFP The Powered Fiber Cable is design to access using only a typical p...

Page 21: ...Two Port PoE Extender Hardware Manual This product is copyright 2017 CommScope LLC All Rights Reserved 17 Cable Split Dimensions Figure 3 1 Cable Split Dimensions 75cm 23cm 24cm 51cm ...

Page 22: ...nder Hardware Manual 18 This product is copyright 2017 CommScope LLC All Rights Reserved 1 Snip the cable end at the indentations in the cable jacket between the center fiber element and the two outer conductor elements ...

Page 23: ...Two Port PoE Extender Hardware Manual This product is copyright 2017 CommScope LLC All Rights Reserved 19 2 Peel one conductor side away to the desired length 75cm by hand ...

Page 24: ...e the cables are smooth to prevent water ingress issues through the grommet 7 Strip the two copper elements to an appropriate length just as accessing any copper cable 8 For the center fiber element simply place the strippers at the desired strip location close the wire strippers fully once then open Now by hand you may pull the center element jacket off revealing the aramid and optical fibers 9 R...

Page 25: ...ly one SFP is connected the data goes via both Ethernet ports Setting the SFP Connection Speed By default both the PoE Extender SFP ports are configured for 1Gbit s If required you can configure one or both to 100Mbit s To change the default configuration 1 Remove the white fiber splice tray for the PoE Extender ...

Page 26: ...or may differ 3 To change the setting for one or both of the SFPs see the illustration below as facing the board in the above images 4 Re install the fiber tray Connecting the Powered Fiber Cable to the PoE Extender 1 Thread the strands through the cap then thread the strands through the supplied grommet Use some silicone grease on the grommet which helps pulling the strands through the ...

Page 27: ...rench tighten the screw cap on the pass through Tighten to torque 1 75Nm 15 5 in lbf Connecting the Power Strands 1 Cut the two power strands to length approximately 14cm Remove 5mm of sheath from the two cables 2 For the 12 AWG cable use a proper 12 AWG or 2MM diameter wire stripper For the 16AWG use a 16 AWG or 1 2mm wire diameter stripper 3 Use tape or heat shrink to prevent the cables splittin...

Page 28: ... strippers fully once then open Now by hand you may pull the center element jacket off revealing the aramid and optical fibers 3 Remove excess aramid as desired for termination This allows the sheath to rest on the beginning of the splice tray 4 The fibers should wrap around the splice tray twice 5 The splice to the fiber connectors should sit in the splice island in the tray as below Note Insert ...

Page 29: ...the splice tray once then connect to the SFPs as below Sealing the PoE Extender 1 Ensure the supplied seal ring is seated in the channel of the PoE Extender and all cables are secured 2 Apply Loctite 222 to all lid bolts Note Field installable connectors such as LightCrimp Plus can be used A clip to connect two LC simplex to one LC duplex is recommended ...

Page 30: ... the screws to torque 2 5Nm 22 1 in lbf It is recommended that you tighten the screws in the opposite corners first for example bottom left then top right bottom right then top left Installing the PoE Extender to Wall or Pole Installing to a Wall The PoE extender has 4 holes on the exterior of the device for attaching to a wall or flat surface ...

Page 31: ...ure reliable operation the PoE Extender should be earthed Make connections from the enclosure earth point using the M5 bolt and washer provided 1 A minimum 16AWG bonding connection from the PoE Extender to the Customer s equip ment earth terminal 2 A minimum 16AWG bonding connection from the PoE Extender to a reliable earth ground point Figure 3 1 PoE Extender Earth Point ...

Page 32: ...t is copyright 2017 CommScope LLC All Rights Reserved Installing to a Pole The PoE extender has 4 holes on the raised sections of the underneath of the device for attaching to a pole via fastenings such as jubilee clips PoE pole mounted with solar shield ...

Page 33: ...Attach your earth connection to the earth point below Operating Temperature Advice At the top of the Two Port PoE Extender s operating temperature range the physical temperature of the PoE Extender may exceed 70ºC Ensure the supplied solar shield is in place for protection See Table 4 2 on page 31 for operating temperature details ...

Page 34: ...Two Port PoE Extender Hardware Manual 30 This product is copyright 2017 CommScope LLC All Rights Reserved ...

Page 35: ...er Two Port PoE Extender PFU P C O 060 02 Table 4 2 Climatic Performance Item Specification Storage Temperature 40ºC to 70ºC Installation Temperature 5º C to 45º C Operating Temperature 40ºC to 65ºC 65 C assumes 45 C ambient air temperature plus 20 C sun loading Table 4 3 Physical Dimensions Item Specification Dimensions including solar shield 283mm x 225mm x 77mm Weight 3 8kg ...

Page 36: ...s is represented along with the two Powered Fiber Cable copper gauge options with supported maximum distances in meters Table 4 4 Electric Transmission Input Voltage Cable Gauge AWG Lmax m PoE PoE Lmax m PoE PoE Lmax m PoE PoE Lmax m PoE Lmax m PoE Maximum 57V 12 650 1120 1570 1595 2630 Maximum 16 255 445 620 630 1040 Nominal 48V 12 460 795 1100 1120 1840 Nominal 16 180 315 435 440 725 Minimum 40 ...

Page 37: ...06 IEC 62368 1 2014 Compliance CE FCC CSA RCM SELV NEC Class 2 input Environmental ETSI EN 300 019 1 4 V2 3 1 2013 08 Class 4 1E EN 60068 2 52 1996 REACH SVHC RoHS2 2011 65 EU EN 60529 1992 A2 2013 IP68 NEMA 6P Table 4 6 Communications Item Specification Optical Input Accepts all MSA compliant 100Base X and 1000Base X SFP transceivers Optical Input Singlemode ITU T G657 A2 Optical Input 50um Multi...

Page 38: ...rted Fiber Cable Types Catalogue Number Cable PFC S02L12 PFC Singlemode 2F I O 12AWG PFC S02L16 PFC Singlemode 2F I O 16AWG PFC S02O12 PFC Singlemode 2F Outdoor 12AWG PFC S02O16 PFC Singlemode 2F Outdoor 16AWG PFC S04L12 PFC Singlemode 4F I O 12AWG PFC S04L16 PFC Singlemode 4F I O 16AWG PFC S04O12 PFC Singlemode 4F Outdoor 12AWG PFC S04O16 PFC Singlemode 4F Outdoor 16AWG PFC S12L12 PFC Singlemode ...