2. Introduction
Page 12
MF0150A3A.doc Manual for ION-M7P/17EHP
2. Introduction
2.1. Purpose
Cellular telephone systems transmit signals in two directions between base
transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, extension of the
transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The
number of the Remote Units depends on the hardware and software configuration.
The Remote Units are connected to the Master Unit with optical links. The optical
loss must be less than 10 dB inclusive optical couplers or splitters.
The Master Unit is the connection to the base transceiver stations. The configuration
of a Master Unit depends on the number of the Remote Units and the frequency
range.
WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the
UL, a wavelength within 1546 nm – 1550 nm is used. For the DL, a wavelength of
1310 ± 10 nm is used. The maximum output power for the UL and DL is 6.7 mW.
2.2. The ION-M7P/17EHP
The ION-M7P/17EHP is a multi-band, multi-operator remote unit configuration used
in conjunction with a Master Unit in the ION optical distribution system. By supporting
the entire AWS-3 spectrum, faster and more reliable wireless service is ensured and
network quality can be improved.
This system transports up to two frequency bands simultaneously (700 MHz and
1700/2100 MHz), providing a cost-effective solution for distributing capacity from one
or more base stations.
The ION system transports signals on the RF layer in a very cost-effective manner
enabling multiple operators to use multiple technologies and move their signals
simultaneously from a cluster of base station to a number of remote locations over
the same fiber.
The ION-M optical distribution system is a cost-effective coverage solution for dense
urban areas, tunnels, subways, airports, convention centers, high-rise buildings and
other locations where physical structures increase path loss.