Ruckus ICX 7450 Switch Hardware Installation Guide
67
Part Number: 53-1003899-09
Managing the Ruckus ICX 7450
•
•
•
•
•
•
Hardware maintenance schedule
Ruckus ICX 7450 switch hardware components require minimal maintenance. Ruckus recommends cleaning the fiber-optic connectors
on a fiber-optic port and the connected fiber cable each time you disconnect the cable.
Replacing a fiber-optic transceiver
You can remove an SFP, SFP+, or QSFP+ transceiver from a slot and replace it with a new one while the Ruckus ICX 7450 is powered on
and running.
This section provides information about the following tasks:
•
Removing a copper or fiber-optic transceiver
•
Cabling a fiber-optic transceiver
•
Cleaning the fiber-optic connectors
Removing a fiber-optic transceiver
While removing a fiber-optic transceiver, be sure to wear an ESD wrist strap that is connected to ground.
To remove a fiber-optic transceiver from an SFP, SFP+, or QSFP+ slot, do the following.
1.
Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack).
2.
Disconnect the fiber cable connector from the port connector.
CAUTION
The procedures in this chapter are for qualified service personnel.
CAUTION
Do not unscrew and remove the top cover of the Ruckus ICX 7450. There are no user-serviceable parts inside the Ruckus
ICX 7450.
CAUTION
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.