![CommScope FlexWave Installation Manual Download Page 14](http://html1.mh-extra.com/html/commscope/flexwave/flexwave_installation-manual_2643833014.webp)
FlexWave
®
Prism Remote Unit and RF Module Installation Guide
FWPP-504-02
Page 10
© May 2017 CommScope, Inc.
Overview of Prism Remote Units
Remote Unit Status LED
This section illustrates the Status LED on a Quad-Bay PRU. The Status LED for the Single-Bay, Dual-Bay, and
Tri-Bay PRUs is in the same location and functions the same as the Status LED for the Quad-Bay PRU.
The Remote Unit has a single red Status LED that is located on the bottom of the chassis. At system startup, the
Status LED is red to indicate that the Remote Unit is powering up and that the SeRF processor does not yet control
the Remote Unit; the Status LED will remain red for approximately one minute. If after three minutes the Status
LED is still red, it indicates the Remote Unit is unable to boot up. (Some common failures that can prevent the PRU
from booting up include a faulty Power Supply, SeRF, or Compact Flash Card.)
Boom of an AC-Powered PRU
Boom of a DC-Powered PRU
Status LED
NETWORK
POWER
48VDC/XXA
MOD D
TX1/RX1
NETWORK
MOD D
TX1/RX1
POWER
100-240 VAC
50-60 Hz
XX AMPS
WARNING:
HIGH LEAKAGE CURRENT. EARTH
CONNECTION ESSENTIAL BEFORE
CONNECTING SUPPLY
MOD D
TX0/RX0
MOD D
TX0/RX0