background image

860576982 
Instruction Sheet 

 

www.commscope.com 

 

Page 2 of 7 

Separately Orderable Components 

Part No. 

Description 

PC-AUS-120-250

 

Engine power cord for Australia, New Zealand: 15A, 250 VAC, 3.6m

 

PC-BRAZIL

 

Engine power cord for Brazil: 10 A, 250 VAC, 2.5m

 

PC-CHINA

 

Engine power cord for China: 16 A, 250 VAC, 3.0m

 

PC-DENMARK

 

Engine power cord for Denmark: 16 A, 250 VAC, 2.5m

 

PC-EU-120-250

 

Engine power cord for Europe: 16 A, 250 VAC, 3.0m

 

PC-INDIA

 

Power cord for India: 16 A, 250 VAC, 2.5m

 

PC-NA-250

 

Engine power cord for United States, Canada, and Mexico: 20 A, 250 VAC, 10 ft 

PC-SWISS

 

Engine power cord for Switzerland: 10 A, 250 VAC, 25m

 

PC-UK-120-250 

Engine power cord for United Kingdom, Hong Kong, Singapore: 13 A, 250 VAC, 3.0m 

TRM-RJ45-EU

 

RJ45 to 18AWG Terminator , per channel

 

 

 

 Important Notes and Recommendations 

 

For installations in Canada, no un-insulated live parts in the output from the

 Redwood

 engine shall be 

readily accessible, as defined by the Canadian Electrical Code (CES). Accessibility shall be determined 
using the risk of shock accessibility criteria such as use of the finger probe from the CSA standard(s) 
cited for the category associated with the c-UL Mark. 

 

Access to such parts should also be considered when removing panels that do not require the use of 
tools when removed. Insulated parts, such as wire or cabling with outer insulation or jacket that are 
certified and carry a sufficient voltage rating (>60V) are permitted to be accessible to contact. 

 

If a fixture requires more than one channel for power, use additional wiring (see each fixture’s 
specification for requirements). Note that all additional channels for a 2- or 3-channel fixture must be 
connected to the same engine. Wiring for an individual fixture cannot be spread across multiple engines. 

 

It is recommended that the fixtures in a single space be interleaved across engines. This provides 
another level of redundancy 

— in the event of an electrical failure affecting an engine, only a portion of 

the lights in a room would turn off. 

 

18 AWG (1mm) cable installations will be wired as with category cable, except that each 18AWG cable 
pair  will  be  terminated  with  a 

Redwood

  RJ45-18AWG  terminator.    These  terminators  will  allow  the 

18AWG pair  to  be connected  to the RJ45 jack  with  no 

other modifications required.  Multi-pair 18AWG 

can be used with multiple 

Redwood

 RJ45-18AWG terminators attached. 

 

The 

Redwood 

engine, director, sensors, gateways and wall switches are designed for commercial use 

only and are not for residential use. 

 

 

Summary of Contents for Engine 3 Model 4834

Page 1: ... or 277 VAC input power converts it to low voltage DC and distributes the power to all fixtures via Redwood LED sensors and gateways using Class 2 low voltage cabling The engine can be located on a rack or wall mounted in an electrical or telecom closet Ordering information is listed below Part No Description ENG 3 4834 250 Engine generation 3 200 250 VAC ENG 3 4834 277 Engine generation 3 277 VAC ...

Page 2: ...he c UL Mark Access to such parts should also be considered when removing panels that do not require the use of tools when removed Insulated parts such as wire or cabling with outer insulation or jacket that are certified and carry a sufficient voltage rating 60V are permitted to be accessible to contact If a fixture requires more than one channel for power use additional wiring see each fixture s...

Page 3: ...ions for connector preparation If using the RJ45 connector it can be wired as T568A straight through or T568B crossover If using 18 AWG 1mm wiring to connect to the engine use a Redwood RJ45 terminator on the 18 AWG wire 6 Install third party light fixtures according to vendor s installation instructions Installation Rack Mount Instructions 1 Attach the two rack mount brackets to each side of the ...

Page 4: ...sing screws not provided that can hold at least 125 lbs 57kg For a typical situation where the drywall is 5 8 16mm thick a 2 51mm or longer drywall screw on each corner of the plywood is recommended 2 Attach the wall mount tray to the plywood backing board using provided screws 3 With power disconnected attach the engine to the wall mount tray using provided screws Mount the engine with the input ...

Page 5: ...continuously as designed a dedicated branch circuit for the engines is recommended preventing other loads on the same circuit from drawing too much current from the branch circuit Provide the engine with a suitable disconnect in the input power distribution so that AC power is safely removed during servicing The wiring must meet all NEC state and local electrical codes and needs to be installed by...

Page 6: ... 2 200W Note Redwood does not furnish any pigtails plugs receptacles conduit or flex cable Engine LED Indicators The engine has a series of LEDs on the front panel to communicate the system s status These LEDs provide information on the engine s operation and the status of port communication Power Indicator Status Power LED Indicator Engine Status Off No power is delivered to the engine Blinking gr...

Page 7: ...ine Port LED Indicator Status Port Status Off No device connection is detected on the port Solid green The engine recognizes the device connection Blinking green The engine is upgrading the firmware of a gateway Solid amber The engine is in the process of discovering a fixture Alternately an error has occurred after discovery Ethernet Indicator Status Ethernet Status Indicator Ethernet Status Off An...

Reviews: