background image

 

860576982 
Issue 5, September 2015 
www.commscope.com

 

 

 

Engine 3 Model 4834 Installation 

 

 

 

 

 

© 2015 CommScope, Inc.   

All rights reserved 

 

Page 1 of 7 

 

For RoHS Inquiries:
CommScope Inc.
Corke Abbey, Bray
Co. Dublin, Ireland
Attn: Legal Department

General 

The 

Redwood

®

 Engine 3 Model 4834 powers and communicates with 

Redwood

 gateways, sensors,  and  wall 

switches

 to  provide intelligent lighting control and building intelligence. The engine provides a sophisticated level of 

control  w h i c h   s

ignificantly reduces energy consumption. Multiple engines can be linked together to  power and 

control hundreds or thousands of 

fixtures. 

The engine provides communications and control for all types of lighting including LED, 

fluorescent, CFL  and HID. 

In the case of LED lighting, the engine also provides centralized AC to DC power conversion. It  takes high voltage 
200

–250 VAC or 277 VAC input power, converts it to low-voltage DC, and distributes  the power to all fixtures via 

Redwood

 LED sensors and gateways using Class 2, low-voltage cabling. The engine can be located on a rack or 

wall mounted in an electrical or telecom closet.

 

Ordering information is listed below:  

Part No. 

Description 

ENG-3-4834-250

 

Engine, generation 3, 200

–250 VAC

 

ENG-3-4834-277

 

Engine, generation 3, 277 VAC

 

 WallMount-Tray-1G 

Engine wall mount kit 

 

Redwood

®

 Engine 3 Model 4834 

How to Contact Us 

 

To find out more about 

CommScope

® 

 products, visit us on the web at 

www.commscope.com/

 

 

For technical assistance: 

-

 

Live technical support for 

Redwood

®

 products is available Monday through Friday from 

8 AM to 5 PM (PST), excluding holidays. 

-

 

Within North and South America, contact your local account representative or technical 
support at 1-800-840-0709 (Option 2).  Outside North and South America, contact your 
local account representative or technical support at +1 510-270-5360 (Option 2). 

-

 

An email can also be sent to [email protected] for technical support. 

 

Summary of Contents for Engine 3 Model 4834

Page 1: ... or 277 VAC input power converts it to low voltage DC and distributes the power to all fixtures via Redwood LED sensors and gateways using Class 2 low voltage cabling The engine can be located on a rack or wall mounted in an electrical or telecom closet Ordering information is listed below Part No Description ENG 3 4834 250 Engine generation 3 200 250 VAC ENG 3 4834 277 Engine generation 3 277 VAC ...

Page 2: ...he c UL Mark Access to such parts should also be considered when removing panels that do not require the use of tools when removed Insulated parts such as wire or cabling with outer insulation or jacket that are certified and carry a sufficient voltage rating 60V are permitted to be accessible to contact If a fixture requires more than one channel for power use additional wiring see each fixture s...

Page 3: ...ions for connector preparation If using the RJ45 connector it can be wired as T568A straight through or T568B crossover If using 18 AWG 1mm wiring to connect to the engine use a Redwood RJ45 terminator on the 18 AWG wire 6 Install third party light fixtures according to vendor s installation instructions Installation Rack Mount Instructions 1 Attach the two rack mount brackets to each side of the ...

Page 4: ...sing screws not provided that can hold at least 125 lbs 57kg For a typical situation where the drywall is 5 8 16mm thick a 2 51mm or longer drywall screw on each corner of the plywood is recommended 2 Attach the wall mount tray to the plywood backing board using provided screws 3 With power disconnected attach the engine to the wall mount tray using provided screws Mount the engine with the input ...

Page 5: ...continuously as designed a dedicated branch circuit for the engines is recommended preventing other loads on the same circuit from drawing too much current from the branch circuit Provide the engine with a suitable disconnect in the input power distribution so that AC power is safely removed during servicing The wiring must meet all NEC state and local electrical codes and needs to be installed by...

Page 6: ... 2 200W Note Redwood does not furnish any pigtails plugs receptacles conduit or flex cable Engine LED Indicators The engine has a series of LEDs on the front panel to communicate the system s status These LEDs provide information on the engine s operation and the status of port communication Power Indicator Status Power LED Indicator Engine Status Off No power is delivered to the engine Blinking gr...

Page 7: ...ine Port LED Indicator Status Port Status Off No device connection is detected on the port Solid green The engine recognizes the device connection Blinking green The engine is upgrading the firmware of a gateway Solid amber The engine is in the process of discovering a fixture Alternately an error has occurred after discovery Ethernet Indicator Status Ethernet Status Indicator Ethernet Status Off An...