PMT200B SERIES DryLine
®
DEHYDRATOR USER MANUAL
19
The standard 115 Vac unit can be run on an
inverter with the input of 24 or 48Vdc inverter.
The inverters are available in either 24 or 48
Vdc. Due to the induction of a dc motor in the
compressor pulling so many amps and the cost
of a dc compressor we choose to power the
units with an inverter to keep the cost down
and reduce the induction load on your battery
systems.
Installing the 24 Vdc to AC inverter
Remove the inverter from its packaging and
install in desired location. The inverter can be
placed on a flat surface or mounted to a wall
via the flanges and slots on the bottom of the
inverter.
Verify power switch is turned off on the inverter.
Connect the power cord from the dehydrator to
the AC receptacle located on the left side of the
inverter.
Connect the DC power to the lugs located
on the right side of the inverter to the battery
system. Ensure the polarity is correct. Improper
connection can damage inverter and void
warranty.
Turn inverter on. Only green LED’s should be
illuminated.
Turn on Dehydrator.