MAINTENANCE
Before doing any maintenance on the ultraviolet sterilizer, the power supply and water
supply must be disconnected. Only in rare situations does the quartz sleeve ever
have to be removed. If necessary use a coin or a large flat head screw driver to gently
and carefully remove the quartz sleeve. If excess force is used the quartz sleeve will
break. After removed use a soft clean cloth to gently remove any excess grim and/or
debris. Reassemble using a small amount of silicone o ring lubricant placed on the o
ring prior to sliding into the main body of the ultraviolet sterilizer.
The PL ultraviolet bulb needs to be replaced every 8,000-9,000 hours. This will insure
optimum performance.
A. Follow all safeguards and warnings
B. Unscrew the threaded PL bulb cap on the end of the ultraviolet sterilizer.
Once unscrewed the inside of the cap will reveal the PL light bulb socket.
C. Remove the PL UV bulb from the box.
Important: Do not touch the quartz
part of the bulb. If needed use a clean cloth to handle the bulb.
D. Align the pins with the holes in the bulb socket. Press the bulb directly into
the holes in the bulb socket. Avoid all angles; failure to do so may cause
permanent damage to the bulb and/or the bulb socket.
E. Screw cap back onto the UV sterilizer.
F. Replacement quartz sleeves and quartz bulbs are available at your
independent dealer.
Note: The efficiency of the Terminator UV Sterilizer depends on the duration the UV
light is contact with the water. Thus the rate of water flow not the way the water travels
will relate to the efficiency of the UV sterilizer.
Specification of the Terminator UV Sterilizer:
Item no.
Capacity
Max. water flow
Wattage
Case Lot UPC #0069037
UVS 5
60 gal.
200 GPH
5 watt
6
1398 6
UVS 9
100 gal.
500 GPH
9 watt
6
1160 9
UVS 13
200 gal.
600 GPH
13 watt
6
1156 2
UVS 18
300 gal.
750 GPH
18 watt
6
1518 8
UVS 24
400 gal.
1,000 GPH
24 watt
6
1519 5
UVS 36
500 gal.
1,250 GPH
36 watt
6
1520 1