Ensure the switch powering the light
fixture is turned to the ON position and
leave it ON at all times to ensure
automatic dusk-to-dawn operation.

SWITCH

CONTROLLED

OPERATION

1

2

DUSK-TO-DAWN MODE

DUSK-TO-DAWN OPERATION

AUTOMATIC

NIGHTTIME ON

DAYTIME OFF

A

Light fixture (A) includes integral photocell for dusk-to-dawn operation which 
enables the light fixture to automatically turn ON when dark outside and turn 
OFF when the sun rises, thus saving you energy.

NOTE:  If photocell is located in an area 
under heavy shade, the photocell may not 
detect enough light and may turn the light 
fixture on.

TIP:  To test if the light fixture and photocell
work properly, run power to the fixture and  
cover the photocell to turn fixture ON. 
Shine a light into the photocell to see if 
fixture turns OFF.

SWITCH CONTROLLED

Switch controlled operation enables the light fixture to
turn ON and OFF by flipping a switch that controls the
electricity to the junction box powering the fixture. The
light fixture will not turn ON and OFF automatically, but is 
manually controlled.

(fig 13).

(fig 14).

9

HOMEDEPOT.com

Please contact 1-844-584-3776 for further assistance.

Summary of Contents for TPAR2-PC-4K-BZ

Page 1: ...e quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Commercial Electric Questions problem...

Page 2: ...ician This light fixture must be properly grounded Make sure connections are secure using wire nuts crimp on lugs or other approved connecting devices This light fixture should be installed outdoors t...

Page 3: ...ippers cutters Circuit tester Safety goggles Work gloves Silicone sealant Ladder Phillips screwdriver Lumens Light Output 1500 Lumens Watts Power Consumption 20 Watts LED Replaces 75W Incandescent Lum...

Page 4: ...Mounting plate bracket pre installed 1 Hanger wire for hands free installation pre installed B A D C HARDWARE KIT NOTE Hardware not shown to actual size AA BB CC DD EE Part Description Quantity AA 8 3...

Page 5: ...ndard recessed junction boxes Junction box must be at least 1 1 2 inch deep for proper installation fig 3 fig 3 fig 1 fig 2 2 SHUT OFF ELECTRIC POWER OFF Verify wall switch is in OFF position fig 4 th...

Page 6: ...ard For eave mount the TOP arrow must point toward the building AA C 4 HANG FIXTURE FROM MOUNTING PLATE BRACKET For hands free mounting place the hanger wire hook into the slot of the mounting plate b...

Page 7: ...re white wire to junction box white wire common the junction box ground wire to the green lighting fixture ground wire which is attached to the mounting plate C fig 9 Black Line White Common Green Gro...

Page 8: ...screws on each lamp head to fix the desired angle From the breaker and switch turn power back ON to the light fixture to verify light fixture illuminates WARNING Risk of fire Keep the lamp heads at l...

Page 9: ...photocell is located in an area under heavy shade the photocell may not detect enough light and may turn the light fixture on TIP To test if the light fixture and photocell work properly run power to...

Page 10: ...tocell Wait several seconds until fixture turns ON Light cycles ON and OFF continuously Photocell light sensor is sensing reflected light Relocate light fixture to a location where there is no reflect...

Page 11: ...abuse misuse or accident or damages caused during shipping Any other products not manufactured by Commercial Electric which have been supplied installed and or used in conjunction with Commercial Ele...

Page 12: ......

Page 13: ...roblems missing parts Before returning to the store call Commercial Electric Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 844 584 3776 HOMEDEPOT COM Retain this manual for...

Reviews: