- When wiring, please use a tool similar to a screwdriver.
Multi Entry Panel
Bld. Distributor
ID : 1
CH 1
ID : 2
CH 2
ID : 3
CH 3
ID : 4
CH 4
1) Wiring Diagram
(Power source from building distributor) (Multi-Entry Panel powered separately)
2) Wiring
— Please pay attention to the polairy of the wires. Units will not work properly when
mis-wired.
— If the distance between the building distributor and the Multi-Entry Panel is within
20m, the power is supplied from the building distributor.
If the distance between the building distributor and the Multi-Entry panel is greater
than 20m, a separate power source (RF-1A for Audio-type Multi-Entry Panels) is
required. The maximum extended distance range cannot exceed 100m. (In the case
of using a separate power source, there is no power line connection between the
building distributor and the Multi-Entry Panel units)
— The allotted ID of the Multi-Entry Unit should match with the assigned number of the
connection terminal of the building distributor (CCU-BD) as follows.
9. System & Wiring Diagram
3)System Diagram