3) Set the dip switches of Building Distributor to match its assigned ID.

4) Run “NAME TOOL_200.exe” file.

5) Select the Building ID in “ Select No ”. on the menu.

6) Select the port connecting with the computer in “ Select Port ” 

7) Select “ Add ” to enter a resident number and name 

5

8) Screen display duration lasts for 30 seconds after receiving a call 

9) Talking duration time last for 60 seconds. 

10) Temperature limit : -10

~ +40

11) Dimension(mm) : 140(W) x 341(H) x44(D)

12) Weight: 1570g

Installation 

Surface Mount Type

Flush Mount Type

Summary of Contents for DRC-MSB

Page 1: ...In Korea 2007 12 Thank you for purchasing our COMMAX product Please carefully read this User s Guide in particular precautions for safety before using the product and follow the instructions to use y...

Page 2: ...5Lux 3 Lux DC24 DC28V 5A powered by building distributor Wiring Power voltage Screen dimension Standby 60mA Maximum operation 450mA Max WhenpowersourceissuppliedfromBuildingDistributor Lessthan20m Wh...

Page 3: ...ti Entry Panel The allotted ID of the Multi Entry Unit should match with the assigned number of the connection terminal of Building Distributor CCU BS When wiring please use a tool like a screwdriver...

Page 4: ...yusingadryclothto preventanybreakdownorelectric shock Do not install the product in a humid place It may cause an electric shock or a fire Do not forcibly pull out the cord from the socket If the cord...

Page 5: ...1 txt shown above Name list shown below will not take priority to be saved over the existing data AptNo1 txt If the socket holes are larger than normal do not put the plug It may cause an electric sho...

Page 6: ...allation all wiring can be used with UTP cable CAT 5 2 Connect up to 4 Multi Entry Panels per building 3 Connect up to 4 residences per single Floor distributor CCU FS 4 Connect Multi Entry Panels wit...

Page 7: ...6 Select the port connecting with the computer in Select Port 7 Select Add to enter a resident number and name 5 8 Screen display duration lasts for 30 seconds after receiving a call 9 Talking duratio...

Page 8: ...of download cable to the serial port of the PC and Connect other side 3P connector to RS232 Port of Building Distributor 11 1 Building Distributor CCU BS one Building Distributor is connected to up t...

Page 9: ...e unit s case 2 While pressing SW2 turn on the Building Distributor and the password will initialize to 4321 and the Lamp will blink for 3 seconds 10 Changing the password 7 1 Press the buttons accord...

Page 10: ...ntry Panel when you press the Door release button on an in house unit 5 Then register the ID of the shown residence and press button to hear a sound of completion 6 The registration is complete when y...

Reviews: