CMD-404FU
(D)
Notes on wiring (It doesn't guarantee the quality of product for
connec-tion if you do not keep the following)
- Wire the "IN" of CMD-404FU
(D)
with distributor or, CMD-404FU
(D)
installed with
"OUT" on
the floor below
- Wire "LINE 1~4" of CMD-404FU
(D)
with 2
nd
CCTV of MODUME system
video
phone.(Max 4 Houses connection)
Lobby phone : Export-oriented type LOBBY (Gate View , Multi panel)
Building distributor: Modum distributor (CMD-101BU) (Required)
Video phone : (DC TYPE) The video phone for 4-wire way Modum system.
(Required)
(CMV-43AD/CMV-77KD/CMV-43SD/CMV-70SD)
Adapter (Power): DC24V / 3A (Required)
Power(DC24V / 3A) input basically should be advised to be installed
with one power supply r per one CMD-404FUD. (Required)
※
5