background image

① The visitor makes a call from the entrance -> the call automat-

ically  goes  to  both  monitor  and  interphone.  Pick  up  the
receiver  to  respond  the  call  (In  case,  if  the  response  was
made by both monitor and the interphone, 3-way conversation
is possible), and/or press the "Door release" button -> the door
opens.

② After putting down the receiver, the call is ended and monitor

display automatically turns off.

③ You can press the "Call button◎" on the monitor -> talk to an

interphone, or press the "Call button◎" of an interphone to talk
to the monitor.

① When  a  call  is  made  by  a  door  camera,  you  can  hear  its

chime sound and see visitor's image from a monitor.
If  there  is  an  interphone  connected,  you  can  talk  through  it
with a visitor as well.

② Pick up the handset if you wish to talk. 

Duration of talk is 60 seconds, after which the visitor's image
will be automatically turned off. Press the "Monitor    " button if
you wish to talk more.

③ Press the "Door release      " button to open the door.
④ Hang up the handset to end the talk ->

Monitor will be automatically turned off.

5

4. Operation 

1) Talk to a visitor from a door camera

① The visitor makes a call from the first camera -> you can hear

the  chime  sound,  and  see  the  visitor's  image  on  the  monitor
with a remark "Cam.1"

② The  visitor  makes  a  call  from  the  second  camera  ->  you  can

hear the chime sound, and see the visitor's image on the mon-
itor with a remark "Cam.2" 

1. Visitor Calls 

1. Visitor Calls 

* Talk to a visitor in case if 2 cameras are connected.

* Call between interphone and a monitor is only possible if the

monitor display is turned on.

2) Talk through an interphone

www.safemag.ru

www.safemag.ru

Summary of Contents for CDV-50N

Page 1: ...nstruction for Users Registered as an electromagnetic radiation compli ant home use product this unit can be installed in all locations including residential areas 1 Greetings 1 2 Warnings and Caution...

Page 2: ...nstruction for Users Registered as an electromagnetic radiation compli ant home use product this unit can be installed in all locations including residential areas 1 Greetings 1 2 Warnings and Caution...

Page 3: ...d place It may cause an electric shock or a fire Do not forcibly pull out the cord from the socket If the cord is damaged it may cause a fire or an electric shock Do not put the plug in the sock et wi...

Page 4: ...direct rays of the sun or heating devices at a time of installation Install the product in a flat and stable place Otherwise it may not function properly Pull the plug if the product is not used for a...

Page 5: ...ew of door cameras 5 Interphone button Call an interphone 6 Door open button Open the door 7 Color adjuster Adjust the screen color 8 Brightness adjuster Adjust the screen brightness 9 Volume Controll...

Page 6: ...rned off Press the Monitor button if you wish to talk more Press the Door release button to open the door Hang up the handset to end the talk Monitor will be automatically turned off 5 4 Operation 1 T...

Page 7: ...l la at ti io on n C Ca am me er ra a I In ns st ta al ll la at ti io on n a at t D DR RC C 4 4M MC C Note Avoid installing the product in the area of direct sunlight The position of the unit s body s...

Page 8: ...r ra a c co on nn ne ec ct to or r 1 Red Talk Audio 2 Blue GND 3 Yellow Power 14V 4 White Call signal P Po ol la ar ri it ty y o of f i in nt te er rp ph ho on ne e c co on nn ne ec ct to or r Note 1...

Page 9: ...tors When adding a second monitor visual and audio quality of video may deteriorate DP 4VHP Extendable CDV 50N DP 4VHP CDV 50N DRC 4MC DRC 4MC 4 wires 4 wires 4 wires 4 wires 4 wires 4 wires www safem...

Page 10: ...ts Monitor CDV 50N 1EA Handset 1EA Wall bracket for monitor 1EA Monitor fixing screw 1EA Wall bracket mounting screw 2EA Connector 4P 3EA User Manual 1EA Screw T4 X 18 2EA Screw M3 X 6 1EA www safemag...

Page 11: ...multaneous communication From a door camera Electric chime From an interphone Beep sound Time to display the screen 60 10sec Distance from camera 28m 0 5 50m 0 65 70m 0 8 Operating Temperature 0 40 32...

Page 12: ...eration failure is detected do not hesitate to contact Service Center All electric power must be blocked by the building blocking device Do not place water bottles or flowerpots upon the product Pleas...

Page 13: ...12 Memo www safemag ru www safemag ru...

Page 14: ...umid place It may cause an electric shock or a fire Do not forcibly pull out the cord from the socket If the cord is damaged it may cause a fire or an electric shock Do not put the plug in the sock et...

Page 15: ...direct rays of the sun or heating devices at a time of installation Install the product in a flat and stable place Otherwise it may not function properly Pull the plug if the product is not used for a...

Page 16: ...ew of door cameras 5 Interphone button Call an interphone 6 Door open button Open the door 7 Color adjuster Adjust the screen color 8 Brightness adjuster Adjust the screen brightness 9 Volume Controll...

Page 17: ...visitor as well Pick up the handset if you wish to talk Duration of talk is 60 seconds after which the visitor s image will be automatically turned off Press the Monitor button if you wish to talk mor...

Page 18: ...W M3 Monitor installation Camera Installation at DRC 4MC Note Avoid installing the product in the area of direct sunlight The position of the unit s body should fit the standard height range Recommend...

Page 19: ...HP Polarity of the camera connector 1 Red Talk Audio 2 Blue GND 3 Yellow Power 14V 4 White Call signal Polarity of interphone connector Note 1 In case if there is a high voltage power line in the area...

Page 20: ...tors When adding a second monitor visual and audio quality of video may deteriorate DP 4VHP Extendable CDV 50N DP 4VHP CDV 50N DRC 4MC DRC 4MC 4 wires 4 wires 4 wires 4 wires 4 wires 4 wires www safem...

Page 21: ...ts Monitor CDV 50N 1EA Handset 1EA Wall bracket for monitor 1EA Monitor fixing screw 1EA Wall bracket mounting screw 2EA Connector 4P 3EA User Manual 1EA Screw T4 X 18 2EA Screw M3 X 6 1EA www safemag...

Page 22: ...multaneous communication From a door camera Electric chime From an interphone Beep sound Time to display the screen 60 10sec Distance from camera 28m 0 5 50m 0 65 70m 0 8 Operating Temperature 0 40 32...

Page 23: ...eration failure is detected do not hesitate to contact Service Center All electric power must be blocked by the building blocking device Do not place water bottles or flowerpots upon the product Pleas...

Page 24: ...12 Memo www safemag ru www safemag ru...

Reviews: