background image

24

20. Miscellaneous

19. Attention when in use

Don’t install this product at different place when it need to be moved to other places as

it is installed with common wiring type 

Please make the device switch up 

Please never make this product disjointed and remodeled. Please consults checking

and repair of this product with dealership or customer consultation counter.

Please do not raise metal object, pot and bottle on the product 

use a proper disconnection device at interior wiring in a building. When the fire

emergency alarm is happened, promptly shut down the disconnection device of

building 

When to install and repair the device, please make the device power off

Please carefully read this User’s Guide before calling service man 

After checking the entire check list, please contact customer service center. We will do

our best to make you satisfy with our services.

Before You Call

Try the Troubleshooting Guide on the following pages. If you still can’t solve your

problem, try one more thing before you call. 

1. Pull the Power Plug from the AC receptacle. 

2. Wait 10 minutes. 

3. Plug the unit back in and try your procedure again.

Getting Help

If you still can’t correct an operating problem, contact your dealer. If your dealer is

unable to solve your problem, contact Commax Customer Service. Please don’t open

the cabinet and attempt to repair the unit, as this will void your warranty. 

Unplug the unit and refer servicing to qualified service personnel when: 

The power supply or plug is damaged. 

The unit has been exposed to rain or water. 

A solid object or liquid ahs fallen into the unit. 

The unit exhibits a distinct change in performance or will not operate normally. 

The unit has been dropped or the cabinet has been damaged. 

Maintaining Your Unit

The only maintenance that your unit should requires is an occasional dusting DO NOT

spray any liquids on the unit. 

To Service The Unit

Customer Service may be reached at 1-080-902-2222

Replacement Parts

When replacement parts are required, be sure the service technician has used

replacement parts specified by the manufacturer or those which have the same

characteristics as the original part. Unauthorized substitutions may result in fire,

electrical shock or other hazards. 

Summary of Contents for CDP-1020IB

Page 1: ...responsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety b...

Page 2: ...Receiving calling button tone 14 13 EMS function Device control 15 14 Detoured call 19 15 Delivery notice 19 16 Guard security function 19 17 Wiring 21 18 Operation tips 23 19 Attention when in use 24...

Page 3: ...tric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it fo...

Page 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Page 5: ...Cannot be used as Slave terminal In case if multiple video phone terminals are installed and the line of one terminal is busy other terminal can overtake the call In case if the line is busy and the...

Page 6: ...GH1T 4X18 ZNW Screws for mounting PHM 3 X 6 ZnY Screws for main body 2P 3EA Connectors 6P 2EA Connectors 8P 1EA Connectors 12P 1EA Connectors 3P 1EA Connectors 4P 1EA Connectors Monitor CDP 1020ID Wal...

Page 7: ...te control Secumax remote metering and control Device control Lighting Gas valve Boiler Security1 Burglar1 For setting Security1 Magnetic sensor Security2 Burglar2 For setting Security2 PIR sensor Del...

Page 8: ...t shows setting menu of PIN after pressing House PIN icon Enter your preferable 4 digits and press for confirmation 3 Extension No setting It shows setting menu of extension No after pressing extensio...

Page 9: ...wer block device in away mode Time setting for security sensor in away mode Value 0 90 sec available Setting delay time Sec You can choose delay time after activating away mode Security sensors get ac...

Page 10: ...sitor image when you get call sound Call indication appears on the upper left of screen Press Talk icon or button to communicate Press Talk end icon to end communication You can make door open by pres...

Page 11: ...PTZ function Caution PTZ function is available when you connect door camera having PTZ function only You should make power off and on when you change with PTZ based door camera Display setting It sho...

Page 12: ...ds talking 2 Receiving a call from Guard It converts with Guard talk after calling sound You can press Talk icon and talk When you press Talk end icon it ends talking Volume control function You can c...

Page 13: ...g guard station gets emergency signal from household How to release emergency function You should check all the circumstances in your house after emergency happened and press Release icon to stop sign...

Page 14: ...n call to neighbor by entering building number press Bldg and house number press Rm Receiving a call It appears Neighbor mark on screen when a call comes from neighborhood and you can talk by pressing...

Page 15: ...ound from Telephone Guard It controls receiving sound from Guard phone Individual door It controls receiving sound from individual door Neighbor It controls receiving sound from Neighbor Call sound It...

Page 16: ...hts off Each device tab is shown automatically after product booting In case a device is not properly connected it does not appear In order to make sure device checking please make power on again If t...

Page 17: ...tus of the assigned valve Individual valve close You can make the available valve close by pressing the switch located below All Gas valve close Press All Close icon to make all valves close 2 Gas con...

Page 18: ...rature display It shows the desired temperature of the room It has 2 controllers basically you can check and control additional controllers by scrolling right and left sides Temperature control You ma...

Page 19: ...y pressing Requesting remote metering data Water It shows Water usage Gas It shows Gas usage Electricity It shows Electricity usage Hot water It shows Hot water usage Heat It shows Heat usage 4 Remote...

Page 20: ...roperly the status of inhouse you may press Release button to deactivate the alarm and it makes alarm sound stopped from guard station You can make it initial stage once you press Return button 2 Alar...

Page 21: ...ncy and security Press Release icon Return icon Caution Burglarsensorwillbereturned tonormalmode aslongasitisworkingproperly Besuretocheckthe doorclosed ornobodyisin IR sensorarea You can makesecurity...

Page 22: ...2V SENSOR GND DC12V LB_VD_CONT 485 B GND 485 A GND DC14V 2 1 DC_IN GND DC14V Diagram Installing SLAVE phones Enter the ID which is an assigned number of each Slave phone for classifying ID in circumst...

Page 23: ...onnecting wires When it is used with security switch lead switch it use and sensor line If you do not want to use security 2 please connect sensor line each other or security sensor 2 away mode will b...

Page 24: ...camera to the place where there is no backlight Blurry screen Due to foreign substance on the lens Remove foreign substance with rug No call to guard station common lobby Appears DATA LINE out of orde...

Page 25: ...ll 1 Pull the Power Plug from the AC receptacle 2 Wait 10 minutes 3 Plug the unit back in and try your procedure again Getting Help If you still can t correct an operating problem contact your dealer...

Page 26: ...wires Power Source 14V 1 8A Communication HANDS FREE Display 25 65Cm 10 1 COLOR TFT LCD DIGITAL Telephone Ringer Call sound Door camera Chime 3 melody 2 times Guard station Melody Door camera 28m 0 5...

Page 27: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2016 09 104 PM011020ID10...

Reviews: