USER GUIDE
23
Technical Specifications – Standard AC Models
(415A-Custom)
Dimensions
(with strobe and ½” mounting spacers) – May vary by model:
Height(Depth) Length
Width
Retracted
11”
47”
34.5”
Extended
88”
52”
34.5”
Recessed installation
13”
58”
40”
Minimum
Weight:
136 pounds
Wiring:
Main Power VAC
10/4 SO cord
50’ provided
Control wiring
22/20 PVC Jacketed
50’ provided
Relay protection:
Lights
Cole-Hersey
3055
100 amps
Other electrical
Cole-Hersey
3055
40 amp
Current Draw / Power Requirements:
Average
Generator Requirement
220 Watt LED
120 VAC/21 amps
3 kW minimum
750 Watt Quartz
s
Lift actuators and rotation motor will cause higher current draw during use.
Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):
Lower stage
1:3 (90 seconds maximum per 5 minute)
Upper stage
1:3 (90 seconds maximum per 5 minute)
Rotation
5-6 Revolutions
Motor Speed:
Lower stage
1.0 inches per minute
12 seconds to full extension
Upper stage
0.5 inches per minute
12 seconds to full extension
Rotation
2.75 RPM at lamp tree
Operation:
Angle of vehicle
15˚ maximum incline
Wind load:
Design maximum
60 mph
Maximum tested
55 mph
Summary of Contents for Knight Series
Page 1: ...K n i g h t S e r i e s ...
Page 3: ...USER GUIDE 3 ...
Page 22: ...KNIGHT2 22 ...
Page 24: ...KNIGHT2 24 Specifications ...
Page 25: ...USER GUIDE 25 Parts Lists Exploded Views ...
Page 26: ...KNIGHT2 26 Exploded View Lower Stage ...
Page 27: ...USER GUIDE 27 ...
Page 28: ...KNIGHT2 28 Exploded View Midplate ...
Page 29: ...USER GUIDE 29 ...
Page 30: ...KNIGHT2 30 Exploded View Lamp Tree ...
Page 31: ...USER GUIDE 31 ...
Page 32: ...KNIGHT2 32 Wiring Schematics ...
Page 33: ...USER GUIDE 33 Holster Box ...
Page 34: ...KNIGHT2 34 ...
Page 35: ...USER GUIDE 35 ...
Page 36: ...KNIGHT2 36 Midplate ...