background image

A.

E.

F.

D.

B.

C.

Kit Includes

Tools Required

A. 
B. 
C. 
D. 
E. 

1- 60343 Motor Mount w/ MM5 series module
2- 40002 8/32 X 1/4” Phillips head screws
1- 50030 8’ Lead w/ VD Connector 
1- 50944 Molex Pigtail
1- 40144 Dogging Hole Cap

•  Cordless Drill

•  Hammer & Pin Punch(recommend) 

•  3/16 & 3/32 drill bit

•  5/16 Nut driver (recommended) 

•  #2 Phillips head screwdriver

v L P - U L- M   K I T

INSERT Instructions  

The Command Access VLP-UL-M-KIT is a  Field-installable motorized latch-pullback kit for the Von Duprin 99/98 & 35/33 series 

devices.

# 2 0 4 5 3 _ c

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w . c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

SPECIFICATIONS:

•  Input Voltage:   24VDC +/- 10%

•  Average Latch Retraction Current: 900mA

•  Average Holding Current: 200mA 

•  Wire Gauge:  Minimum 18 gauge

•  Direct wire run - no relays or access control units in-between power supply & module

Recommended Power Supplies:

All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you 
plan on using a non-Command power supply it must be a filtered & regulated linear power supply.

G.

Fire rated dogging kit

1- 50872- Fire Rated Drilling Template (Old Devices)
1- Replacement Dogging Tail Piece (40006 + 40800 + 50872)

F.
G. 

Summary of Contents for VLP-UL-M KIT

Page 1: ...o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 SPECIFICATIONS Input Voltage 24VDC 10 Average Latch Retraction Current 900mA Average Holding Current 200mA Wire Gauge Minimum 18 gauge Direct wire run no relays or access control units in between power supply module Recommended Power Supplies All Command Access exit devices fie...

Page 2: ... fail 5 beeps with pause in between for 30 seconds then device attempts to retract again After 3rd fail 5 beeps every 7 minutes device will not attempt to retract To Reset Depress bar for 5 seconds at any time PUSH TO SET Device is ready to record its new position Troubleshooting Diagnostics 4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly Replace sensor if problem persists ...

Page 3: ... from baserail 4 5 If your device has dogging flip baserail over remove 2 screws securing dogging assembly to rail If you have an older device with rivets you will need to drill them out or use a pin punch to knock them out U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Page 4: ...stallation Instructions Pins Grab your motor and insert attaching bracket at slight angle through the window on the dogging tail 8 9 Straighten kit depress back activating bracket gently pull back on the motor to slide mounting bracket UNDERNEATH baserail U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 ...

Page 5: ...Slide housing back onto baserail push pad Make sure the baserail the black push pad guides are in the correct channel 13 U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 Re install push pad onto baserail 12 Re install 2 screws into mounting bracket housing 14 ...

Page 6: ...location If not repeat steps 15 16 17 U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 PTS Button Step 1 To enter PTS mode Depress MM5 button apply power The device will emit 1 SHORT beep The device is now in PTS mode Step 2 While depressing the push pad apply power i e presenting the credential to...