![COMM-connect SWR TRUE Operator'S Manual Download Page 4](http://html1.mh-extra.com/html/comm-connect/swr-true/swr-true_operators-manual_2642159004.webp)
7
8
Power On/Off
Pressing the ON/OFF button will switch on the instrument. A welcome screen will
appear like this:
The instrument will run for the duration of the auto power off period.
Pressing the Fc button on the keyboard will give a screen with an entry field
Center = pressing the numeric keys you can enter any frequency from 30MHz
to 2700MHz. To correct entry you can use the arrow keys. Press the enter key to
change the center frequency.
Note that the Center frequency will have priority over the Frequency span (FΔ)
making automatic adjust to fit inside instrument range.
Pressing the FΔ button on the keyboard will give a screen with an entry field
Span = pressing the numeric keys, you can enter any frequency span from 0MHz
to 2670MHz. To correct entry you can use the arrow keys. Press the enter key to
change the frequency span.
Note that the frequency span will be adjusted automatic to fit within the range
boundaries and the actual center frequency.
Center Frequency
Frequency Span
Marker
The marker functions are controlled by the arrow keys when the instrument is in
sweep mode. By pressing the left or right arrow the marker line moves across the
screen. When the key is held pressed, a mini cursor will be seen moving across
the screen and when the key is released, the marker will appear in the new posi-
tion. The marker will display the frequency and the measured value of the marker
position on the bottom line. If you press the “ENTER” key, the marker position
will move to the center of the screen and adjust the frequency span symmetrical
on both side of the new center fre- quency.
When “HOLD” is pressed, the sweep position indicator stops at the current posi-
tion and freezes the screen. In “HOLD” mode the frequency sweep is stopped and
depending on the setting of Oscillator, the RF is either On or Off. (see menus)
The “COPY” key will write the screen contents to the USB Memory stick or to the
USB Serial Device. The “COPY” function will create a Directory with the date as
directory name YYYYMMDD e.g. 20080826. In the directory the screen files are
written as .BMP with the time stamp as file name HHMMSS e.g. 164852.BMP .
During write to USB the busy icon is on, when busy goes off, it is safe to remove
the USB device.
Hold and Copy